EasyManua.ls Logo

Sontex Supercal 739 - 13.3 Coaxial M77 x1.5 Meter Data

Sontex Supercal 739
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Instruction for use | Supercal 739
Qn Threaded
connection
*EAS
Mounting
length
*EAS
Mat PN Maximal
ow
qs
Minimal
ow
qi
Low ow
threshold
value
(50°C)
Threaded
hole for
sensor
Total
Meter
Weight
Kvs value
(20°C)
Pressure
loss at
qp
m
3
/h G'' DN mm bar m
3
/h l/h l/h Kg m
3
/h bar
(EN
ISO
228-1)
0.6 3/4" (15) 110 Brass 16 1,2 12 8 yes 0.8 1.7 0.08
1.5 3/4" (15) 110 Brass 16 3,0 15 10 yes 0.8 3.4 0.19
1.5 1" (20) 130 Brass 16 3,0 15 10 yes 0.8 3.4 0.19
2.5 1" (20) 130 Brass 16 5,0 25 17 yes 0.9 5.2 0.23
13.3 Coaxial multi jet meter with M77 x 1.5 connection
*EAS = base 16 bar = 1.6 MPa
Mounting
The Supercal 739 should not be mounted on the side where the continuous operating temperature of
the liquid exceeds 90°C or is below 5°C.
Length of straight section tted upstream/downstream of each ow meter (EN1434): U0 / D0 for:
L=110mm and L=130mm
qp1.5
qp0.6
qp2.5
0.01
0.1
1
0.1 1 10 100
Pressure loss [bar] ==>
Flow [m3/h] ==>
Pressure loss
Sontex Supercal 739
log-log
Pressure loss curve

Other manuals for Sontex Supercal 739