ā€œ
CDP-101
3-1.
MECHANISM
ADJUSTMENTS
Optical
Pick-up
Position
Adjustment
This
adjustment
determines
the
position
when
the
i
;
optical
block
is
at
its
innermost
position
on
the
disc,
It
is
done
so
that
the
optical
block
can
read
the
infor-
mation
recorded
in
the
TOC
(Table
of
Contents)
on
the
disc
lead-in
track.
S908
limit
switch
Display
increases
when
turned
counterclockwise.
(Optical
block
moves
toward
the
disc
outer
circumference.)
Perform
this
adjustment
after
adjusting
so
that
clearance
(A)
is
approximately
2.6
mm
when
the
ad-
justment
screw
is
removed.
:
1.
Turn
POWER
switch
on
and
insert
disc
(YEDS-1).
2.
Press
>PLAY
button
and
adjust
the
adjustment
screw
so
that
the
display
window
reading
is
as
shown
in
Figure
A.
i
The
timer
counter
decreases
approximately
10—20
H
seconds
with
one
counterclockwise
turn
of
the
adjustment
screw.
When
turning
the
adjustment
screw,
press
the
OPEN/CLOSE
button
to
reset
the
microcomputers
(IC101,
102,
103).-
After
this,
press
>PLAY
button,
read
display
window
and
perform
adjust-
ment
again.
Display
decreases
when
turned
clockwise.
(Optical
block
moves
toward
the
disc
inner
circumference.)
SECTION
3
ADJUSTMENTS
3.
Press
OPEN/CLOSE
button,
and
after
the
LED
on
the
OPEN/CLOSE
button
lights
up,
press
>
PLAY
button.
Confirm
that
the
display
window
reading
is
as
shown
in
Figure
A.
This
can
also
be
confirmed
by
displaying
the
re-
maining
time
by
pressing
LAP/REMAINING
TIME
button,
.
Repeat
step
3
about
ten
times.
If
there
is
even
one
variation
from
the
figure,
repeat
steps
2-3.
.
Press
>PLAY
button
to
obtain
PLAY
mode.
Press
Auto
Selection
(
P|
)
button
and
Manual
Search
(>>>)
button
so
that
the
outermost
circum-
ference
is
played.
Next
press
RESET
button.
.
Confirm
that
play
begins
when
>PLAY
button
is
pressed.
If
it
does
not,
the
optical
block
and
OP
base
are
touching,
so
push
the
optical
block
motor
worm
gear
by
hand
in
the
direction
of
the
arrow,
as
shown
in
Figure
B,
and
rotate
it
1-2
times.
Turn
the
adjustment
screw
clockwise
one
rotation,
and
repeat
steps
2-6.
1.
SCAN
Indicator
lights
up.
3.
SCAN
Indicator
goes
out.
display
window
2.
Timer
Counter
indicates
9.
0c
—
oa
-
G88
TRACK
NO.
MINUTE
SECOND
DISC
SET
Fig.
A
Rotate
worm
gear
1—2
turns
-by
hand
in
the
direction
of
the
arrow.
gear
(C),
(D)
optical
sled
motor
a