13
CFD-G500/G500L
digital
voltmeter
100 k
TP (VT)
i
jack (J321)
set
32
level meter
(range: 0.5–5 V ac
)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
TP (FM IN)
FM RF signal
generator
0.01
µ
F
set
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
TUNER SECTION 0 dB = 1 µV
AM Section
Setting:
RADIO BAND•AUTO PRESET button: AM, MW or LW
Connecting Level Meter (FM, AM or MW and LW)
Connecting Digital Voltmeter (FM, AM or MW and LW)
•Repeat the procedures in each adjustment several times, and
the frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
AEP, UK, East European, Russian Models
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
MW FREQUENCY COVERAGE CHECK
Frequency Display 531 kHz 1,611 kHz
Reading on Digital voltmeter 1.0 ± 0.5 V 5.2 ± 0.6 V
Adjustment Part <confirmation> <confirmation>
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1 CT3
621 kHz 1,404 kHz
LW FREQUENCY COVERAGE ADJUSTMENT
Frequency Display 153 kHz 279 kHz
Reading on Digital voltmeter 0.6 ± 0.3 V 5.0 ± 0.1 V
Adjustment Part <confirmation> L4
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2 CT5
162 kHz 261 kHz
US, Canadian, E, Singapore, Australian Models
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display 530 kHz 1,710 kHz
Reading on Digital voltmeter 1.0 ± 0.05 V 5.3 ± 0.7 V
Adjustment Part L4 <confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 CT3
620 kHz 1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display 87.5 MHz 108 MHz
Reading on Digital voltmeter 1.3 ± 0.3 V 3.0 ± 0.2 V
Adjustment Part <confirmation> L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1 CT1
87.5 MHz 108 MHz
Adjustment Location: See page 14.
FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM