MECHANICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads pinch rollers
erase head rubber belts
capstan idlers
2. Demagnetize the record/playback head with a head demag-
netizer. (Do not bring the head magnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode Torque meter Meter reading
FWD CQ-102AS
2.95 – 6.86 mN • m
(30 – 70 g • cm)
(0.42 – 0.97 oz • inch)
FWD
back tension
CQ-102C
0.15 – 0.53 mN • m
(1.5 – 5.5 g • cm)
(0.021 – 0.076 oz • inch)
FF CQ-201AS
more than 5.88 mN • m
(more than 60 g • cm)
(more than 0.83 oz • inch)
REW CQ-201B
more than 5.88 mN • m
(more than 60 g • cm)
(more than 0.83 oz • inch)
Tape Tension Measurement
Mode Tension meter Meter reading
FWD CQ-403A
more than 100 g
(more than 3.53 oz)