CFD-S03CP/S03CPL
TUNER SECTION 0 dB = 1 µV
[AM (MW/LW)]
Setting:
Function: RADIO/BAND/AUTO PRESET
Band: MW or LW
[FM]
Setting:
Function: RADIO/BAND/AUTO PRESET
BAND button: FM
Connecting Digital Voltmeter (FM, MW and LW)
•Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer
capacitors.
Remove FM antenna in FM adjustment.
+
i
jack (J321)
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level:
as low as possible
Put the loop
antenna close to
the set.
level mete
r
set
32
set
i
jack (J321)
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level:
as low as possible
level meter
32
0.01
µ
F
MAIN board
TP ANT2 (JW231, 232)
+
digital voltmete
r
TP (VT)
TP (GND)
100 k
MAIN board
AM (MW/LW) IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1 450 kHz
LW FREQUENCY COVERAGE ADJUSTMENT (AEP)
Adjustment Part Frequency Display Reading on Digital Voltmeter
L3 279 kHz 5.3 ± 0.5 V
Confirmation 153 kHz 0.6 ± 0.05 V
LW TRACKING ADJUSTMENT (AEP)
Adjust for a maximum reading on level meter
ANT1-2 162 kHz
CT5 261 kHz
MW FREQUENCY COVERAGE ADJUSTMENT (AEP)
Adjustment Part Frequency Display Reading on Digital Voltmeter
Confirmation 531 kHz 0.9 ± 0.2 V
Confirmation 1,611 kHz 5.5 ± 0.5 V
MW FREQUENCY COVERAGE ADJUSTMENT
(EXCEPT CND, AEP, E92, MX)
Adjustment Part Frequency Display Reading on Digital Voltmeter
L3 531 kHz 0.8 ± 0.05 V
Confirmation 1,611 kHz 5.0 ± 0.5 V
MW FREQUENCY COVERAGE ADJUSTMENT (CND, E92, MX)
Adjustment Part Frequency Display Reading on Digital Voltmeter
L3 530 kHz 0.8 ± 0.5 V
Confirmation 1,710 kHz 5.8 ± 0.05 V
MW TRACKING ADJUSTMENT (EXCEPT CND, E92, MX)
Adjust for a maximum reading on level meter
ANT1-1 621 kHz
CT3 1,404 kHz
MW TRACKING ADJUSTMENT (CND, E92, MX)
Adjust for a maximum reading on level meter
ANT1-1 620 kHz
CT3 1,400 kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
L6 10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part Frequency Display Reading on Digital Voltmeter
L2 108 MHz 3.0 ± 0.2 V
Confirmation 87.5 MHz 1.5 ± 0.5 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1 87.5 MHz
CT1 108 MHz
Adjustment and Connecting Location:
MAIN board (See page 15)
•Abbreviation
CND : Canadian model
E92 : AC 120V area in E model
MX : Mexican model
Ver. 1.2