27
7EH, 07H, 05H, 47H, 0AH, 11H, FFH
6.29 MODEL REQUEST
Function: To check model information.
Data length: 2 bytes
Data: 02H, 10H
Details of function: Information about recording function of MDS can be shown by this
command.
Example of transmission packet:
Check model information.
7EH, 07H, 05H, 47H, 20H, 10H, FFH
6.30 STATUS REQ
Function: To check the condition of mecha deck.
Data length: 2 bytes
Data: 20H, 20H
cause malfunction such that MDS sends out an incorrect track num-
ber.
Example of transmission packet:
Cancel edit operation just before the current operation.
Details of function: This is the command to make MDS send out “STATUS DATA” indicat-
ing current mecha deck condition.
When this command is sent, MDS sends out “STATUS DATA”.
“STATUS DATA” contains information such as exist/no exist of disc,
the value of REPEAT MODE, the value of PLAY MODE and so on.
Example of transmission packet:
Make MDS send out “STATUS DATA”.
7EH, 07H, 05H, 47H, 20H, 20H, FFH