EasyManua.ls Logo

Sony MDS-E12 - 3-6. Auto Diagnosis Function; Operation Procedure; 3-7. Information; 3-8. Measure When Memory NG Appears

Sony MDS-E12
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
Details of function: Indicates to enter Combine rehearsal condition.
When MDS receives a “COMBINE MODE REQ”, it enters Combine
rehearsal condition and outputs this information and “STATUS”.
Example of receive packet:
Entered Combine rehearsal.
6FH, 07H, 05H, 47H, 20H, 8CH, FFH
7.31 EDIT COMPLETE
Function: EDIT has completed.
Data length: 2 bytes
Data: 20H, 8DH
Details of function: Indicates that EDIT has completed.
When Divide, Combine, Erase and Move have completed, MDS out-
puts this information.
Example of receive packet:
EDIT has completed.
6FH, 07H, 05H, 47H, 20H, 8DH, FFH
7.32 DIVIDE POINT DATA
Function: Current Divide Point
Data length: 3 bytes
Data: 20H, 8EH, Position
Position: -128(80H) to +127(7FH)
Details of function: When MDS receives “DIVIDE ADJUST” command during the track
divide rehearsal with “DIVIDE MODE REQ” command, it changes di-
vide planed point to the position provided by Position and outputs this
information.
At “DIVIDE MODE REQ” command, even if the divide planed point
changes drastically, MDS outputs “DIVIDE POINT DATA” at each time
the value varies by 1.
The track cannot be divided right after the track starts and right before
the track ends. Therefore, at “DIVIDE MODE REQ”, if absolute value
of specified position is large, the value sometimes does not reach the