SECTION
2
SERVICE
NOTES
2-1,
SERVICE
MODE
When
the
test
lands
on
the
panel
board
are
shorted,
this
set
will
enter
the
Test
Mode.
This
allows
you
to
test
the
fluores-
cent
indicator
tube
and
the
LED
display
and
to
turn
power
ON/OFF.
Short
these
two
lands
with
tweezers,
etc.
3%
The
Test
Mode
cannot
be
entered
unless
the
POWER
is
turned
ON.
(1)
POWER
ON
In
this
set,
the
control
(AU
BUS)
of
the
power
amplifier
TA-H6800N
is
used
to
turn
the
power
ON/OFF.
Without
this
power
amplifier,
even
if
100Vac
is
input,
the
set
will
be
always
in
the
STANDBY
(POWER
OFF)
state
and
any
test
other
than
clock
operation
check
cannot
be
performed.
Also,
any
power
supply
to
the
AUDIO
system
(A+10V,
DSP+5V)
is
OFF
and
so
any
energization
check
by
sound
input
is
not
allowed.
Therefore,
the
POWER
ON
test
lands
should
be
used
to
turn
the
power
ON
before
entering
repair.
(2)
POWER
OFF
This
changes
from
POWER
ON
to
STANDBY
state.
The
fluorescent
indicator
tube
display
will
be
of
half
brightness
to
display
the
clock.
(3)
TEST
MODE
In
the
POWER
ON
state,
when
the
Test
Mode
lands
are
shorted
once:
@
All
LED
indicators
are
totally
lit.
(VIDEO
1
and
VIDEO
2/MD/DAT
are
lit
orange
due
to
simultaneous
illumina-
tion
of
red
and
green.)
@
One
vertical
line
appears
on
the
fluorescent
indicator
tube
surface
and
moves
from
left
to
right.
At
this
time,
make
sure
that
this
vertical
line
is
not
partially
thicker.
{
||
=>
@®
The
fluorescent
indicator
tube
display
is
totally
lit
and
this
operation
is
stopped.
Make
sure
that
the
display
is
illuminating
equally
without
unevenness.
Each
time
the
Test
Mode
land
are
shorted,
the
following
operations
are
performed
in
turn:
Dolby
sound
in
DSP
menu
is
selected
and
@
The
parametric
equalizer
is
set
to
3dB
up
at
1kHz.
@®
The
parametric
equalizer
is
set
to
6dB
up
at
1kHz.
©
The
set
returns
to
the
STANDBY
state
and
the
clock
displays
“0:
00”
(Cold
Start).
All
the
parameters
includ-
ing
clock
will
be
reset.
2-2.
SERVICE
POSITION
For
this
set,
with
the
front
and
rear
panels
open,
remove
4
screws
securing
the
power
transformer
and
1
screw
securing
the
AC
inlet.
Then,
by
facing
the
power
transformer
down
as
shown
below,
all
the
boards
can
be
repaired.
MONITOR
board
POWER
board
|
|
INLET
board
DSP
board
MICOM
board