9
Location and Function of Parts
Rear Panel
a - AC IN (AC power input) A and B connectors 
(3-pin)
Connect to 100 to 240 V AC power supply with the 
optional AC power cords.
Depending on the configuration of your unit when 
shipped, the HK-PSU04 Power Supply Unit may not be 
installed. In that case, the AC IN B connector is not used.
Note
For information about installing an HK-PSU04 Power 
Supply Unit, contact your Sony service representative.
b U (signal ground) terminal
Connect to the system ground.
c FM (frame memory) DEVICE connector 
(IEEE1394 compliant)
This connector is for attaching an external hard disk drive 
for frame memory.
For details of hard disk drives that can be used with the 
MVS-6000 system, consult your Sony service 
representative.
d GPI (General Purpose Interface) connector (D-sub 
25-pin)
Connect to external devices for input and output of trigger 
signals. Up to eight inputs and eight outputs are possible, 
with input and output conditions set on the center control 
panel.
e REMOTE 1 to 4 connectors (D-sub 9-pin, RS-422A 
compliant)
These connectors are used to control the auxiliary bus of 
the MVS-6000 series from external devices, or to operate 
the MVS-6000 from editing control systems such as the 
BVE-9100.
Define the types of the connected devices on the center 
control panel.
f DME CTRL (Digital multi effect control) 
connector (RJ-45 compliant) (MKS-6470)
Connect to an Ethernet
* switch.
The MVS-6000 system’s center control panel is connected 
in the same way to the Ethernet switch to form a network 
for exchange of signals between the devices.
This network is used primarily to control the various 
devices from the center control panel of the MVS-6000 
system.
g DME DATA (Digital multi effect data) connector 
(RJ-45 compliant) (MKS-6470)
Connect to an Ethernet
* switch.
The MVS-6000 system’s center control panel is connected 
in the same way to the Ethernet switch to form a network 
for exchange of signals between the devices.
h CTRL (control) connector (RJ-45 compliant)
Connect to an Ethernet
*
 switch.
The MVS-6000 system’s center control panel is connected 
in the same way to the Ethernet switch to form a network 
for exchange of signals between the devices. 
This network is used primarily to control the various 
devices from the center control panel of the MVS-6000 
system.
i FM DATA (frame memory data) connector (RJ-45 
compliant)
Connect to an Ethernet* switch. This is a dedicated LAN 
connector for image data.
j DATA connector (RJ-45 compliant)
Connect to an Ethernet* switch.
1-AC IN A and B connectors
2U terminal
3FM DEVICE connector
4GPI connector
5REMOTE 1 to 4 connectors
6DME CTRL connector
qdMONITOR OUT 25 to 32 connectors
qsPRIMARY INPUTS 1 to 49 connectors
qaREF INPUT connectors
0DATA connector
9FM DATA connector
8CTRL connector
7DME DATA connector
qfOUTPUTS 1 to 24 and FC 1, 2 connectors