• Adjustment method of VC PWM Duty (H)
(mode number: 765)
1. Select the manual mode of the test mode, and set the mode
number 765. (See page 13)
2. Connect a digital voltmeter to the AP913 (VC) on the MAIN
board, and adjust
[EASY SEARCH +] key (voltage up) or
[EASY SEARCH --] key (voltage down) so that the voltage
becomes 2.75 ± 0.02 V.
Proceed to the next step without pressing X key if voltage is
already adjusted.
3. Press the X key to write the adjusted value.
• Adjustment method of VREM PWM Duty (H)
(mode number: 766)
1. Select the manual mode of the test mode, and set the mode
number 766. (See page 13)
2. Connect a digital voltmeter to the AP912 (VL) on the MAIN
board, and adjust [EASY SEARCH +] key (voltage up) or
[EASY SEARCH --] key (voltage down) so that the voltage
becomes 2.75 ± 0.02 V.
Proceed to the next step without pressing X key if voltage is
already adjusted.
15
56
14
10
5
1
C912
C913
C915
C924
C925
C926
R5
D903
AP912
(VL)
AP909
(GND)
MAIN BOARD
digital
voltmeter
AP912 (VL)
AP909
(GND)
(SIDE A)
VchPWM
765
LCD display
3. Press the X key to write the adjusted value.
• Adjustment method of VREM PWM Duty (L)
(mode number: 767)
1. Select the manual mode of the test mode, and set the mode
number 767. (See page 13)
2. Connect a digital voltmeter to the AP912 (VL) on the MAIN
board, and adjust [EASY SEARCH +] key (voltage up) or
[EASY SEARCH --] key (voltage down) so that the voltage
becomes 2.5 ± 0.02 V.
Proceed to the next step without pressing X key if voltage is
already adjusted.
3. Press the X key to write the adjusted value.