– 19 –
CD RF LEVEL CHECK
Connection :
Adjustment Method :
1. Set the ser vo mode of the test mode (Mode : 000).
2. Press the ( ke y, and set the CD test adjustment mode
(Mode : 050) using the VOLUME + or – ke y.
3. Press the = or + ke y and mo ve the optical pic k-up to
the center circumference.
4. Inser t a test CD (TD YS-1).
5. When the ( ke y is pressed, the CD FE balance adjustment
mode (Mode : 052) will be set after CD focus search adjust-
ment mode (Mode : 051).
6. When the ( ke y is pressed, the CD ABCD le vel adjustment
mode (Mode : 053) is set.
7. Press the P ke y to perf orm automatic adjustment, and c hec k
that the RF le vel is 1.1 ± 0.3 Vp-p.
digital voltmete
r
MAIN board
AP5117 (VCC)
AP574 (LDI0)
oscilloscope
MAIN board
AP5500 (RF)
AP5430 (VC)
8. Chec k that the v olta g e between AP5117 (VCC) and AP574
(LDI0) and at this time is belo w 40 mV .
9. Press the p ke y.
10. Exit the test mode.
1.0
±
0.3 Vp-p
(RF waveform)
AP574
(LDI0)
AP5117
(VCC)
AP5430
(VC)
AP5500
(RF)
BP801
(TEST)
IC501
CN501
IC503
IC509
TP5980
(TE)
– main board
(side B) –
– main board
(side B) –
Adjustment Location :