Record/Playback
Head
Azimuth
Adjustment
Procedure:
1.
Mode
:
FWD
playback
Test
tape
P-4-A100
VTVM
(10kHz,
—10dB)
LINE
OUT
2.
Turn
the
adjustment
screw
for
the
maximum
output
levels.
If
these
levels
do
not
match,
turn
the
adjustment
screw
until
both
of
output
levels
match
together
within
1dB.
L-CH
peak
within
10B
R-CH
Screw
Peak
we
——~
angle
position
L-CH
peak
R-CH
peak
3.
Phase
Check
Mode:
playback
Test
tape
P-4-A100
(10kHz,
—10dB)
ill
ae
47kO
Oscilloscope
LINE
OUT
4.
Confirm
that
the
phase
difference
between
L-CH
and
R-CH
is
in-phase
to
90°.
Oscilloscope
Lissajous’
Figures
QOOAOQOO
eT
good
no
good
in-phase
45°
go°
135°
=
180°
J
Adjustment
Location:
Adjusting
screw
Playback
Level
Adjustment
Procedure:
1.
Mode:
playback
Test
tape
P-4-L300
(315Hz,
OdB)
LINE
OUT
2.
Adjust
the
RV101
(L-CH)
and
RV201
(R-CH)
to
satisfy
the
following
specification.
Adjustment
Value:
LINE
OUT
level
:
302
338mV
(-—8.2
—7.2dB)
Level
difference
between
channels:
within
0.5dB
Confirm
that
the
LINE
OUT
level
does
not
change
when
playback
and
stop
are
repeated.
Erase
Current
Adjustment
Procedure:
1.
Mode:
record
Blank
tape
F
VTVM
TP503
requency
counter
CS-413
2.
Adjust
RV506
so
that
VTVM
reading
is
110mV
(erase
current
110mA).
3.
At
this
time,
confirm
oscillation
frequency.
Adjustment
Value:
Erase
current:
11072mA
Oscillation
frequency:
160+6kHz