EasyManua.ls Logo

Sony TC-K808ES - Bias Consumption Current Adjustment; Metal Bias Adjustment; Calibration and Level Meter Adjustment

Sony TC-K808ES
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Blas
Consumption
Current
Adjustment
Note:
The
bias
consumption
current
must
be
adjusted
before
adjusting
the
record
bias.
Retry
record
bias
adjustment
after
the
bias
consumption
current
is
adjusted.
Procedure:
1,
Set
semi-fixed
resistors
RV104
(L-CH),
RV204
(R-CH)
and
RV505
for
record
bias
adjustment
to
mechanical
center,
and
select
the
recording
mode
without
applying
a
signal.
Adjust
T101
(L-CH)
and
T201
(R-CH)
so
that
the
digital
voltmeter
reading
becomes
minimum.
Digital
voltmeter
B+
(+8.5V)
Specification:
120mV
or
less
(This
value
is
measured
using
CS-413
after
bias
adjustment.)
Blas
and
Recording
level
adjustment
Condition:
REC
LEVEL
control:
Specified
recording
position
(Page
9)
Procedure:
1.
2.
Mode:
simultaneous
record
and
playback
LINE
IN
315Hz,
25mV
(—30dB)
AF
7
10kHz,
25mV
(—30dB)
Blank
tape
10kQ
CS-222
Ay
Bass
Le
Oscilloscope
VTVM
J
[eo}}
{C4
LINE
OUT
Adjust
the
following
controls
so
that
the
minimum
output
becomes
the
specified
output
level.
(1)
RV104
(L-CH)
and
RV204
(R-CH)
srrrrsreres
Bias
adjustment
(2)
RV103
(L-CH)
and
RV203
(R-CH)
serrrtssees
Recording
level
adjustment
Adjustment
Value:
(1)
Level
of
10kHz
against
315Hz:
0+0.3dB
(2)
315Hz
level:
30.9
33.1mV
(—28.0
—27.4dB)
Metal
Bias
Adjustnemnt
Condition:
REC
LEVEL
control:
Specified
recording
position
(page
9)
Procedure:
1,
Mode:
simultaneous
record
and
playback
315Hz,
25mV
(—30dB)
Pelee
10kHz,
25mV
(--30dB)
Blank
tape
€)
oKQ.
LINE
IN
CS-413
(e)
Attenuator
ey
Looo*
LINE
OUT
2.
Adjust
RVSO5
so
that
10kHz
R-CH
output
is
0+0.3dB
relative
to
the
315Hz
output.
Calibration
Adjustment
and
Level
Meter
Adjustment
Condition:
CALIBRATION
switch:
ON
Procedure
(oscillation
output
level
adjustment):
1,
Mode:
record
(No
signal
to
LINE
IN)
VIM
Blank
tape
[A
TP501
CS-222
2,
Adjust
RV508
so
that
the
400Hz
check
point
level
is
2.32
—2.59V
(9.5dB—10.5dB).
3.
Adjust
RV507
so
that
the
8kHz
check
point
level
is
2.32
2.59V
(9.5dB—10.5dB).
Procedure
(level
meter
adjustment):
1.
Record
mode
(No
signal
to
LINE
IN)
2.
Adjust
RV102
to
higher
side,
then
lower
it
gradually.
Adjsut
so
that
the
level
“‘a”
higher
by
one
point
than
0dB
of
LOW
FREQ
segment
(lower)
of
CAL
level
meter
turns
off.
3.
Adjust
RV202
so
that
HIGH
FREQ
segment
(upper)
up
to
0dB
position
of
CAL
level
meter
turns
on.
HIGH:
Blinking
of
level
“a”
higher
by
1
point
is
acceptable.
HIGH
REC
CAL
FREQ
L
oem
mem
wae
ee
ee
LOW
Bo ew
ee
eee
oe
ee
oe
FREQ
REC
EO
CAL
NOP
“gy!
LOW:
Blinking
of
level
“a”
higher
by
1
point
is
not
acceptable.

Related product manuals