– 13 –
Bias Consumption Current Adjustment DECK B
This adjustment should be performed when replacing the head assy
or the bias oscillator transformer (T141, T241).
Setting:
REC LEVEL knob : standard recording position (See page 11.)
Procedure:
1. Connect the digital voltmeter to test point TP441.
2. Set RV141 (L-CH), RV241 (R-CH) to mechanical center.
3. Press the · button to playback.
4. Adjust T141 (L-CH), T241 (R-CH) so that the digital voltmeter
reading becomes minimum.
Adjustment Value: Maximum 220 mV
Adjustment Location: MAIN board (See page 14.)
Record Bias Adjustment DECK B
Setting:
REC LEVEL knob : standard record position (See page 11.)
Procedure:
1. Set to test mode (See page 11.)
2. Insert a tape into deck B, press the REC r button and then
press the · button to start recording.
3. Record Mode
Record Level Adjustment DECK B
Setting:
REC LEVEL knob : standard record position (See page 11.)
Procedure:
1. Set to test mode (See page 11.)
2. Insert a tspe into deck B, press the REC r button and then
press the · button to start recording.
3. Record Mode
4. Playback Mode
set
321
blank tape
CS-413
TP441
L-CHR-CH
digital
voltmeter
LINE IN
no signal
set
AF OSC
attenuator
10 k
600
LINE IN
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
blank tape
CS-123
4. Playback Mode
set
recorded
portion
level mete
r
LINE OUT
47 k
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If the selevels do not adjustment level, adjust the RV141 (L-CH)
and RV241 (R-CH) to repeat steps 3 and 4.
Adjustment level:
The palyback output of 10 kHz level difference against 315 Hz ref-
erence should be ± 0.5 dB.
Adjustment Location: MAIN board (See page 14.)
set
AF OSC
attenuator
10 k
600
LINE IN
blank tape
CS-123
315 Hz, 50 mV (–23.8 dB)
set
recorded
portion
level mete
r
LINE OUT
47 k
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If the selevels do not adjustment level, adjust the RV101 (L-CH)
and RV201 (R-CH) to repeat steps 3 and 4.
Adjustment Value:
LINE OUT level : –23.8 ± 0.5 dB (47.2 to 53.0 mV)
Adjustment Location: MAIN board (See page 14.)
w
w
w
.
x
i
a
o
y
u
1
6
3
.
c
o
m
Q
Q
3
7
6
3
1
5
1
5
0
9
9
2
8
9
4
2
9
8
T
E
L
1
3
9
4
2
2
9
6
5
1
3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299
http://www.xiaoyu163.com
http://www.xiaoyu163.com

Other manuals for Sony TC-WE435

Related product manuals