Adjustment Using the Menus
68
SERIAL REMOTE KEY INHIBIT menu
You can lock the setting so that they cannot be changed
by an unauthorized user.
Select OFF or ON.
If you set to ON, all items are displayed in black,
indicating the items are locked.
Submenu Setting
SERIAL REMOTE
MONITOR
CONTROLLER
CONNECTION
Selects the mode to be used.
OFF: SERIAL REMOTE does
not function.
ETHERNET: The monitor is
controlled by the command
of Ethernet.
BKM-15R/16R: Sets BKM-
15R or BKM-16R.
Sets the monitor setting.
MONITOR ID: Sets the ID
of the monitor.
GROUP ID: Sets the group
ID of the monitor.
IP ADDRESS: Sets the IP
address.
SUBNET MASK: Sets the
subnet mask.
(255.255.255.000)
DEFAULT GATEWAY:
Sets the default gateway on
or off.
ADDRESS: Sets the default
gateway.
CANCEL: Selects to cancel
the setting.
CONFIRM: Selects to save
the setting.
Sets the address of the remote
controller.
IP ADDRESS: Sets the IP
address.
SUBNET MASK: Sets the
subnet mask.
(255.255.255.000)
DEFAULT GATEWAY:
Sets the default gateway on
or off.
ADDRESS: Sets the default
gateway.
CANCEL: Selects to cancel
the setting.
CONFIRM: Selects to save
the setting.
Sets the connection of the monitor
and the controller.
PEER TO PEER: for one
to one connection
LAN: for connection via a
network
KEY INHIBIT: xx
KEY INHIBIT

Table of Contents