825, 850 Digital Meter

Questions and Answers

  • B
    Brittany HoodAug 18, 2025
    Why does my Sotera 825 Measuring Instruments meter read high?
    • O
      Omar KennedyAug 18, 2025
      If your Sotera Measuring Instruments meter reads high, it could be due to air in the system or the wrong calibration factor. To resolve this, prime the system and fix any suction leaks at the pump. Alternatively, use a higher calibration factor.
  • A
    Andrea RussellAug 20, 2025
    What to do if my Sotera 825 Measuring Instruments meter won't turn on?
    • S
      Susan PatelAug 20, 2025
      If your Sotera Measuring Instruments meter won't turn on, the batteries may be dead, or the electronics module could be damaged or contaminated. Replace the batteries. If that doesn't work, replace the electronics module and gaskets.
  • J
    Jordan MartinezAug 22, 2025
    What to do if my Sotera 825 meter is not consistent?
    • W
      webbhelenAug 23, 2025
      Inconsistent readings on your Sotera Measuring Instruments meter can stem from air in the system, particulates in the fluid, or a worn/damaged meter chamber. Try priming the system and fixing any suction leaks at the pump. Install a screen in front of the meter. Cleaning or replacing the chamber may also help.
  • C
    Carly BurgessAug 26, 2025
    What to do if my Sotera 825 is leaking fluid at inlet/ outlet port?
    • E
      eoneillAug 26, 2025
      If your Sotera Measuring Instruments meter is leaking fluid at the inlet/outlet port, it could be due to needing thread sealant or a cross-threaded port. Add Teflon pipe tape to the joint. If the port is cross-threaded, replace the body.
  • C
    Carrie HodgesAug 28, 2025
    What to do if Sotera 825 Measuring Instruments meter reads low by more than 10%?
    • P
      plopezAug 28, 2025
      If your Sotera Measuring Instruments meter reads low by more than 10%, the meter chamber may be worn, partially plugged, or damaged. You can recalibrate the meter with water, clean the chamber, or replace the chamber and recalibrate the meter.
  • J
    Jessica MercadoAug 30, 2025
    What to do if my Sotera 825 meter Err1 is displayed?
    • S
      Seth DunnAug 30, 2025
      If your Sotera Measuring Instruments meter displays 'Err1', it could be due to damaged electronics or a software fault. You can try to repair or replace the electronics. Alternatively, press 2 and then recalibrate the meter.
  • B
    Billy JenkinsSep 2, 2025
    What to do if my Sotera Measuring Instruments meter fluid flows; meter won't count?
    • V
      Victoria SteeleSep 2, 2025
      If fluid flows but your Sotera Measuring Instruments meter won't count, the meter disk might be sticking, or the driver/magnet may be damaged, or the meter has failed. Clean out the meter chamber. If that doesn't work, repair or replace the chamber assembly or the entire meter.
  • R
    rodney58Sep 4, 2025
    What does Err0 mean on my Sotera 825?
    • R
      Rachel WalkerSep 4, 2025
      If your Sotera Measuring Instruments meter displays 'Err0', it indicates a calibration error or damaged chamber. Recalibrate the meter using a more accurate container. If the error persists, replace the chamber.
  • K
    Kimberly CantuSep 7, 2025
    Why is my Sotera 825 meter display flashing or dim?
    • K
      Kristina RichmondSep 7, 2025
      A flashing or dim display on your Sotera Measuring Instruments meter indicates low batteries. Replace the batteries to resolve this issue.
  • J
    Judith CampbellSep 9, 2025
    What to do if my Sotera Measuring Instruments meter reads low by 10% or less?
    • J
      Jordan MeyerSep 9, 2025
      If your Sotera Measuring Instruments meter reads low by 10% or less, the calibration factor may be incorrect. Use a lower calibration factor.

Summary

Safety Instructions

Technical Information

General Description

Fluid Compatibility

Installation

Changing Meter Readout Position

Procedure to change the position of the meter readout.

Operational Functions

Use

Calibration Using the CAL Factor

1-Step Calibration Procedure

Maintenance

Thorough Cleaning

Steps for cleaning a meter plugged with chemical or debris.

Storage

Instructions for storing the meter in a cool, dry place.

Troubleshooting Guide

825;850 Meter Parts List

Appendix A

To Change Units of Measure

Procedure to change the meter's unit of measure to ounces, pints, quarts, gallons, or liters.

Special Units

Steps to set the meter to use custom 'special' units for measurement.

Reset Accumulated Total

Method to reset the meter's accumulated total to zero.

Meter Check

Procedure to check the meter's calibration and pulses per gallon.

FLSH (FLUSH) Mode

Instructions for using FLSH mode for flushing without affecting totals.

Appendix B

Water Calibration

Procedure for recalibrating the meter using clean water.

Appendix C

Fluid Calibration (other than water)

Procedure for calibrating the meter with fluids other than water using CAL factors.

Appendix D

Meter Calibration Factor Selection Based on Fluid Viscosity

Graphs to help select the correct calibration factor based on fluid viscosity.

CE Certification Information

Details on CE certification and compliance with European directives and standards.