Quick Start Guide for ST600 Series Frequency Inverters Important Function Parameter Settings
13
P01.18
Terminal-Based
Operating Command
Protection At Power-On
0: Terminal-based operating commands are in-
active at power-on
1: Terminal-based operating commands are active
at power-on
0
P02.00
Type Of Motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
P02.01
Rated Power Of AM 1
0.1–3000.0kW
Model-
dependent
P02.02
Rated Frequency Of
AM 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
P02.03
Rated Speed Of AM 1
1–60000rpm
Model-
dependent
P02.04
Rated Voltage Of AM 1
0–1200V
Model-
dependent
P02.05
Rated Current Of AM 1
0.8–6000.0A
Model-
dependent
P02.15
Rated Power Of SM 1
0.1–3000.0kW
Model-
dependent
P02.16
Rated Frequency Of
SM 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number Of Pole Pairs
Of SM 1
1–128
2
P02.18
Rated Voltage Of SM 1
0–1200V
Model-
dependent
P02.19
Rated Current Of SM 1
0.8–6000.0A
Model-
dependent
P02.23
Counter-Emf Of SM 1
0–10000
300
P03.00
Speed-Loop
Proportional Gain 1
0.0–200.0
20.0
P03.01
Speed-Loop Integral
Time 1
0.000–10.000s
0.200s
P03.03
Speed-Loop
Proportional Gain 2
0.0–200.0
20.0
P03.04
Speed-Loop Integral
Time 2
0.000–10.000s
0.200s