EasyManua.ls Logo

Southwire 10031S - Introduction; Safety Warnings; Input Limits

Southwire 10031S
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Introduction
The Southwire 10031 S multimeter measures AC and
DC
voltage,
DC
current, and resistance. It also tests continuity
and 1.5V and 9V batteries. Other features include a large LCD
display, display HOLD, and Auto Power Off. Flip the meter over
and on the back side there are several features to make your life
easier such as test lead storage,
an
integrated kickstand, and
the ability
to
add a Southwire magnetic hanging strap (Model#
60151R).
Your Southwire 10031S multimeter is fully tested and calibrated.
With proper use, it will provide many years
of
reliable service.
I A WARNINGS I
Read, understand and follow the Safety Rules and Operating
Instructions
in
this manual before using this meter.
The meter's safety features may not protect the user if not
used
in
accordance to the manufacturer's instructions.
Ensure that the test leads are fully seated in the input jacks
and keep fingers behind the finger guards when taking
measurements.
Before changing functions using the rotary function switch,
always disconnect the test leads from the circuit under test.
Use only UL listed test leads with the proper safety category
rating.
Comply with all safety codes. Use approved personal
protective equipment when working near live electrical
circuits - particularly with regard
to
arc-flash potential.
Use caution on live circuits. Voltages above 30VAC RMS,
42VAC peak,
or
60VDC pose a shock hazard.
Do not use meter
or
test leads if they appear damaged.
Do not use the meter if it operates incorrectly. Protection
may be compromised.
Verify operation before using meter by measuring a known
live voltage.
Do not use the meter in wet or damp environments
or
during
electrical storms.
Do not use the meter near explosive vapors, dust
or
gasses.
Do not operate meter while Low Battery warning is on.
Replace the battery immediately.
Do not apply voltage or current that exceeds the meter's
maximum rated input limit.
Input Limits
Function
Maximum
Input
Voltage
AC
or
DC
600VAC
RMS/
600VDC
pA/mA
DC
Current
0.5A
fast
acting
fuse
660V
AC/DC
1
0A
DC
Current
1
0A
fast
acting
fuse
600V
AC/DC
(<5A,
30
seconds
max
every
15
minutes,
>5A,
10
seconds
max
every
15
minutes)
Resistance/Continuity
600VAC
RMS/600VDC
Battery
Test
600VAC/DC
2

Related product manuals