Cranking Test
Tester prompts as following:
Use the Up/Down button to select 12V or 24V cranking system, press the key to select.
Tester will go to next screen.
Starting the engine as prompted, tester will automatically complete the cranking test and
display the result.
Normally, in a 12V system cranking voltage value lower than 9.6V is regarded as abnormal
and it is OK if it is higher than 9.6V.
Test result of the tester includes actual cranking voltage and actual cranking time.
When cranking test is abnormal, battery test result will also be displayed at the same time.
This is for the convenience of the maintenance personnel to quickly know the whole state
of the starting system according to the data. After testing finished, do not shut down the
engine, select Charging Test to do Charging test.
Note: If press Enter key once the testing result comes up, then it will remind the user
want to print the test result or not.
If print, press Enter key, if not, press Exit button to return the previous menu.