SIM Inverter Monobloc Air-to-Water Heat Pump
Performance
(all data based on pure water)
SIM-036 HEATING
SIM-036 COOLING
30 40 50 60 70 80 90
Heating Capacity 13,191 17,406 21,621 25,833 30,140 34,447 38,755
BTU/hr
COP5.014.93 4.884.844.464.214.04
Heating Capacity 11,062 14,836 18,611 22,386 26,086 29,785 33,488
BTU/hr
COP4.013.87 3.793.743.643.573.52
Heating Capacity 10,539 12,621 14,700 16,782 19,536 22,294 25,048
BTU/hr
COP2.972.91 2.882.852.812.782.75
Heating Capacity 8,2569,829 11,406 12,980 15,007 17,038 19,065
BTU/hr
COP2.182.25 2.312.352.292.252.22
30 40 50 60 70 80 90
Heating Capacity 12,116 16,014 20,086 24,154 28,222 32,294 36,366
BTU/hr
COP3.703.54 3.473.433.313.223.16
Heating Capacity 9,215 13,065 16,915 20,765 24,427 28,089 31,751
BTU/hr
COP3.203.06 2.982.942.882.842.81
Heating Capacity 7,345 10,200 13,300 15,345 18,219 21,089 23,963
BTU/hr
COP2.502.37 2.292.232.182.152.13
Heating Capacity 4,150 6,703 9,256 11,809 14,362 16,915 19,468
BTU/hr
COP1.781.82 1.841.851.881.911.93
30 40 50 60 70 80 90
Heating Capacity 18,150 19,256 20,362 21,471 26,004 30,536 -
BTU/hr
COP2.802.69 2.602.522.352.24-
Heating Capacity 12,058 14,270 16,485 18,696 22,471 27,007 -
BTU/hr
COP2.502.33 2.212.132.142.20-
Heating Capacity 8,240 11,320 13,481 14,529 17,444 20,362 -
BTU/hr
COP1.451.57 1.681.791.791.79-
Heating Capacity 3,413 5,782 8,154 10,522 13,345 16,167 -
BTU/hr
COP1.131.27 1.341.381.441.48-
36°F DB,
34°F WB
19°F DB,
18°F WB
5°F DB,
3°F WB
19°F DB,
18°F WB
5°F DB,
3°F WB
Ambient
Temp.
Compressor
Frequency
Return Water Temperature: 122°F, Supply Water Temperature: 131°F
45°F DB,
43°F WB
5°F DB,
3°F WB
Ambient
Temp.
Compressor
Frequency
Return Water Temperature: 104°F, Supply Water Temperature: 113°F
45°F DB,
43°F WB
36°F DB,
34°F WB
19°F DB,
18°F WB
Ambient
Temp.
Compressor
Frequency
Return Water Temperature: 86°F, Supply Water Temperature: 95°F
45°F DB,
43°F WB
36°F DB,
34°F WB
0
8,000
16,000
24,000
32,000
40,000
48,000
20 30 40 50 60 70 80 90 100
Capacity, BTU
Compressor Frequency
SIM-036 Heat Capacity 86F RWT
45F DB,
43F WB
36F DB,
34F WB
19F DB,
18F WB
5F DB,
3F WB
0
8,000
16,000
24,000
32,000
40,000
48,000
20 30 40 50 60 70 80 90 100
Capacity, BTU
Compressor Frequency
SIM-036 Heat Capacity 104F RWT
45F DB,
43F WB
36F DB,
34F WB
19F DB,
18F WB
5F DB,
3F WB
0
8,000
16,000
24,000
32,000
40,000
48,000
20 30 40 50 60 70 80 90
Capacity, BTU
Compressor Frequency
SIM-036 Heat Capacity 122F RWT
45F DB,
43F WB
36F DB,
34F WB
19F DB,
18F WB
5F DB,
3F WB
1.00
2.00
3.00
4.00
5.00
6.00
20 30 40 50 60 70 80 90 100
COP
Compressor Frequency
SIM-036 Heat COP 86F RWT
45F DB,
43F WB
36F DB,
34F WB
19F DB,
18F WB
5F DB,
3F WB
1.00
2.00
3.00
4.00
5.00
20 30 40 50 60 70 80 90 100
COP
Compressor Frequency
SIM-036 Heat COP 104F RWT
45F DB,
43F WB
36F DB,
34F WB
19F DB,
18F WB
5F DB,
3F WB
1.00
2.00
3.00
4.00
5.00
20 30 40 50 60 70 80 90
COP
Compressor Frequency
SIM-036 Heat COP 122F RWT
45F DB,
43F WB
36F DB,
34F WB
19F DB,
18F WB
5F DB,
3F WB
30 40 50 60 70 80 90
Cooling Capacity 8,128 10,757 16,904 20,28523,768 26,603 30,837
BTU/hr
EER 9.90 10.14 10.24 10.00 9.62 9.42 9.22
Cooling Capacity 8,025 10,689 16,836 20,21723,666 27,149 30,735
BTU/hr
EER 9.42 9.80 10.079.739.399.189.04
Cooling Capacity 7,991 10,655 16,768 20,11423,564 27,115 30,394
BTU/hr
EER 9.18 9.52 9.93 9.56 9.28 9.04 8.81
Cooling Capacity 7,957 10,587 16,665 20,04623,495 27,047-
BTU/hr
EER 8.94 9.28 9.69 9.42 9.18 8.87 -
30 40 50 60 70 80 90
Cooling Capacity 12,70416,631 21,00224,486 28,41331,350 34,423
BTU/hr
EER 11.74 12.32 12.9712.56 11.67 11.40 11.26
Cooling Capacity 12,46516,563 20,66124,281 28,24231,520 34,594
BTU/hr
EER 11.23 11.98 12.4211.84 11.06 10.89 10.65
Cooling Capacity 12,15716,085 20,25123,359 27,93530,394 34,082
BTU/hr
EER 10.31 10.72 11.6410.85 9.83 9.66 9.42
Cooling Capacity 11,44015,538 19,63622,368 25,613- -
BTU/hr
EER 9.39 10.03 10.44 9.80 8.77 --
Return Water Temperature: 59°F, Supply Water Temperature: 50°F
86°F DB
95°F DB
Ambient
Temp.
Compressor
Frequency
Return Water Temperature: 46°F, Supply Water Temperature: 37°F
86°F DB
95°F DB
104°F DB
104°F DB
113°F DB
113°F DB
Ambient
Temp.
Compressor
Frequency
0
6,000
12,000
18,000
24,000
30,000
36,000
42,000
48,000
20 30 40 50 60 70 80 90 100
Capacity, BTU
Compressor Frequency
SIM-036 Cooling Capacity 45F RWT
86F DB
95F DB
104F DB
113F DB
0
6,000
12,000
18,000
24,000
30,000
36,000
42,000
48,000
20 30 40 50 60 70 80 90 100
Capacity, BTU
Compressor Frequency
SIM-036 Cooling Capacity 59F RWT
86F DB
95F DB
104F DB
113F DB
8.00
9.00
10.00
11.00
12.00
20 30 40 50 60 70 80 90 100
EER
Compressor Frequency
SIM-036 Cooling EER 45F RWT
86F DB
95F DB
104F DB
113F DB
8.00
9.00
10.00
11.00
12.00
13.00
14.00
20 30 40 50 60 70 80 90 100
EER
Compressor Frequency
SIM-036 Cooling EER 59F RWT
86F DB
95F DB
104F DB
113F DB
Water temperatures shown in the following tables are controlled by the Heating Target Temperature Set point. This is the temperature
of the water returning to the heat pump from the system. The supply water temperature will be higher than the Return Target
Temperature. Settings that will result in supply temperature in excess of 131°F are not recommended and cannot be expected to be
achieved under all conditions.
Water temperatures shown in the following table(s) are controlled by the Cooling Target Temperature Set point. This is the temperature
of the water returning to the heat pump from the system. ("INLET" temperature on the home screen) The supply water temperature
("OUTLET" temperature on the home screen) will be lower than the Return Target Temperature. Settings that will result in the supply
temperature below 37°F are not recommended and cannot be expected to be achieved under all Conditions.