Spectra 1759MG 1
Part 1: Introduction
1.1 Features
• Up to 15 fully programmable zones
• Two completely independent partitions. Many of the features and options in the Spectra System can be independently set for
each partition such as Event Reporting, Entry/Exit Delay, Auto-arming and many more. All zones, the keyswitches and all user
codes are assigned to specific partitions, which makes this a true partitioned system.
• Communication bus facilitates the adding, programming and monitoring of all expansion modules
• 1 Installer Code and 48 user codes (including: 1 System Master, 2 Masters, and 1 Duress)
• 2 on-board, fully programmable outputs (PGMs) and one 5A alarm relay
• Simple, direct and logical programming
• Event Call Direction: The Spectra 1759MG control panel events are divided into 5 groups of events. Each of these event
groups can be programmed with a separate dialing sequence.
• Two 32-digit monitoring station telephone numbers and one 32-digit Backup Telephone Number
• Contact ID, Pager Format and many more High-Speed Communication Formats
• "False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay Before
Alarm Transmission, and Recent Closing Report
• Regular arming, Stay arming, Instant arming, Force arming, One-touch arming, Auto-arming, or Keyswitch arming
• 256 Event Buffer with time stamp
• Telephone Line Supervision
• Keypad activated panic alarms
• Compatible with Winload Security System Management Software for Windows®
1.2 Specifications
1.2.1 Spectra 1759MG Control Panel
• AC Power: 16Vac transformer (refer to Table 1 on page 2) with minimum 20VA rating (Rec.:
40VA), 50 to 60Hz
• Battery: 12Vdc, 4Ah/7Ah
•Aux. Power:
+
600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
• Bell Output:
++
1A, fuseless shutdown @ 3A
• PGM Outputs: PGM1 = 150mA low-current output, PGM2 = 1A high-current output
• Alarm Relay: One form “C” relay rated @ 125V, 5A receptive load
• Approvals: 433MHz
868MHz
Compliant to all EU and EFTA countries except Greece according
to RTT&E directives.
1.2.2 Spectra Keypads (1686H, 1686V, 1689 and 1641)
• Power input: Typically 9-16Vdc
• 1 standard keypad zone
• On-board anti-tamper switch (optional)
1686H and 1686V 10-Zone LED Keypad
• Current consumption: 62 to 116mA
1689 16-Zone LED Keypad
• Current consumption: 50 to 117mA
1641 32-Character LCD Keypad
• Current consumption: 60 to 80mA
• PGM: 1 with 50mA current limit
• LCD: Super Twisted Nematic display (STN), Wide viewing angle, Backlight & Contrast
adjustable
Specifications may change without prior notice
+
Cannot exceed 200mA for UL installations
++
Cannot exceed 1A for UL installations

Table of Contents