* The transformer VA rating must be greater or equal to the sum of VA ratings of
all connected lamps.
These cable lenghts are calculated with worst case voltage drops in the
electrical wiring.
MAXIMUM AND STABLE LIGHT OUTPUT IS ONLY GUARANTEED WHEN
THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE
ADVISED VALUES IN THE ABOVE TABLE
SELECT
CABLE SECTION & MAXIMUM LENGTH
LAMP TYPE 1,5mm
2
2,5mm
2
4,0mm
2
6,0mm
2
10mm
2
VA TRANSFORMER
(12VAC)*
PLP050-WH
PLP050-WW
PLP050-BL
122m 204m 326m 490m 820m 8 VA
PLP050-RGB
79m 132m 212m 318m 530m 12 VA
PLP100-WH
PLP100-WW
PLP100-BL
26m 43m 69m 104m 173m 32 VA
PLP100-RGB
15m 25m 41m 61m 100m 48 VA
PLP170-WH
PLP170-WW
PLP170-BL
11m 19m 30m 46m 75m 66 VA
PLP170-RGB
8m 14m 23m 35m 57m 80 VA