Advanced Settings Display
Parameter Description
Time Current Time setting
Region Unit of measure used, METRIC (litre) and US (gallon) options are available
Language
System language used on the valve display, 10 different language options in total for your choice
English,Spanish,French,Russian,Turkish,German,Polish,ltalian,Dutch and Chinese.
Water Hardness This value is water hardness of the raw water supply. It is used to calculate the system capacity.
People Number
Number of people in the household and the calculated reserve capacity. When remaining
reaches reserve capacity a regeneration will be scheduled.
Holiday Mode
When set to ON, the system will perform a Backwash and a Rinse if there is no water flow
detected a er 7 days.The Backwash and Rinse duration can be set in the Regeneration Cycle.
Regen. Mode
Calendar Clock
The unit will initiate a regeneration at the next pre-set regeneration time based on the interval of
days between regeneration days.
Meter Immediately
The unit will initiate a regeneration immediately aer the system capacity remaining reaches
zero.
Meter Delayed
When the system capacity reaches zero, the system will initiate a regeneration at the next pre-
set regeneration time.
Meter Override
When the volume remaining goes below the system capacity, the system will regenerate at the
regen time or when REGEN. DAYs present has passed. Whatever occurs first.
Regen. Time This setting controls the time of day when a regeneration will start
Water Usage This setting is the water average usage
Water Capacity This setting is the total water volume the system can treat aer one complete regeneration
Resin Volume
This setting is the amount of ion exchange media used in the system.The value is used to
calculate system capacity and refill time.
Salt Amount This setting will determine the salt dosage used per regeneration.
Salt Eciency
This setting is the amount of capacity which a certain amount of salt can restore. The value is
used to calculate system capacity and refill time.
Reserve Capacity This value is used to calculate the reserve capacity. Reserve Capacity= No. People x Daily Reserve.
Regen. Cycle
Backwash Control the backwash duration during regeneration cycle
Brine Control the brine duration during regeneration cycle.
Rinse Control the rinse duration during regeneration cycle.
Refill Control the refill duration during regeneration cycle.
Restore Defaults Restore settings to the factory default.
Pre-Fill
If the brine Pre-Fill is ON,the percentage of water pre-set that will be added to the brine tank aer
a regeneration. The default is 70%. The remaining amount of water will be added just prior to the
regeneration and will be proportional to the amount of capacity le in the system.
Salt Check
Soener will check the salt level in the brine tank automatically, in the event of system short of
salt, display will beep to remind you to add salt.
System regeneration based on
automatic calculation
System regeneration based on
manual settings