8. TROUBLESHOOTING
MALFUNCTION Cause Solution
Pressuregaugehas
readingover1bar
Dirty lter bed Backwash the lter (position 4)
Pressureistoolow Hair and lint strainer basket is dirty;
Pump gels too little water
Clean the hair and lint strainer; check the
suction line and the water level
Air in the pump Poor seal on the in-take side of the
pump.
Tighten hose clamps and connecting
ttings.
Leakinglter Seal Defective Check the seal, replace if needed
Pump does not run Not plugged in Check the socket and power cord
G.F.C.1/ or main circuit breaker tripped Switch on the breaker (if it is immediately
tripped again, there is a defect in pump
or controls)
Pump motor defective Replace the entire pump
Sand in Pool If the sand is newly replaced, the under-
sized grains are still present
Backwash several limes until the
backwash water is clear (position 4)
Sand in Central Valve (from back-wash) Purge into drainpipe for 30 seconds
(position 6)
Separation wall in lter is improperly
in-stalled
Check the separation wall for proper
positioning
Filter bottom strainer is damaged Replace the lter bottom strainer
Airinsystem Loosen, but do not remove, the
transparency cover on the lter tank to
allow any trapped air to escape. Tighten
the cover once ail of the air has escaped
For more technical information, missing
parts or in the case of a complaint,
please contact our customer service: