EasyManua.ls Logo

Spitwater SHW76 - User Manual

Default Icon
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
ORIGINAL INSTRUCTIONS
OPERATING AND MAINTENANCE
MANUAL
MADE IN AUSTRALIA
BY
SPITWATER AUSTRALIA PTY LTD
953 METRY STREET
NORTH ALBURY NSW 2640
AUSTRALIA
WARNING: Read and understand this instruction manual before operating this
unit and retain for future reference.
Failure to follow operating, safety and maintenance instructions outlined in this
manual releases the manufacturer from any responsibility for any accidents or
damage incurred and may render any warranty void.
ELECTRIC HOT WATER
HIGH PRESSURE
CLEANER
MODEL NO:
SHW76 (SW110)
SHW76/A (SW110)
SHW76/AS (SW110)
SHW76/R (SW110 ARMY)

Questions and Answers

  • D
    Dylan GriffithAug 12, 2025
    How to fix a Spitwater SHW76 Pressure Washer when the motor doesn't start?
    • A
      Angela AlvaradoAug 12, 2025
      If the motor does not start when you activate the switch, consider these potential causes: * The plug may not be properly connected. Ensure the plug is securely connected. * If your model has a low water cut-off, it might be activated. Check that the water or diesel tank is full, and add water or diesel as needed. * There may be no power supply. Contact an authorized electrician to inspect the power supply.
  • L
    Leslie MoralesAug 19, 2025
    What to do if Spitwater SHW76 motor hums but won't run?
    • R
      Robert HarveyAug 19, 2025
      If, when activated, the motor hums but doesn't run, it could be due to: * An incorrect extension cable. Replace it with an extension cord of the correct size and length, as described in the manual. * Incorrect or insufficient voltage or amperage. Contact an authorized electrician to check the power supply. * A failed capacitor. Contact a Spitwater service agent.
  • E
    Edward JordanAug 27, 2025
    Why is my Spitwater SHW76 Pressure Washer pump running but not reaching full pressure?
    • R
      Robert AustinAug 27, 2025
      If the pump is running but not reaching its rated pressure, there could be several reasons: * The pump might be sucking air. To resolve this, check the hose and fittings for any leaks. * The nozzle could be blocked or worn. Try removing and cleaning the nozzle. * The water filter might be dirty. Inspect and clean the water filter.
  • K
    Kristin RichardsSep 2, 2025
    What to do if my Spitwater SHW76 Pressure Washer has fluctuating pressure?
    • J
      Jacqueline TorresSep 2, 2025
      If your Spitwater Pressure Washer has fluctuating pressure, it could be due to: * The pump sucking air. Check the hose and fittings for leaks. * A blocked or worn nozzle. Remove and clean the nozzle. * A dirty water filter. Check and clean the water filter.

Spitwater SHW76 Specifications

General IconGeneral
ModelSHW76
CategoryPressure Washer
TypeHot Water
Max Pressure3000 PSI
Flow Rate15 L/min
Heating MethodDiesel Burner
PumpTriplex
Hose Length10m