BANTAM
OPERATIONAL INSTRUCTIONS
Revision 2.0
PAGE 1 WWW.4X4sPOD.COM
1. Positive battery cable connection
2. DIP switches (see page 2)
3. Negative battery cable connection
4. Mounting hardware
5. Accessories terminal block for switches 5-8
6. Input terminal block (see page 3)
7. Jumper for input polarity selection (see page 3)
8. Controller inputs (Ethernet cable)
9. 2AMP fuse for circuit board protection
10. Cover. Do NOT remove or warranty will be voided
11. Accessories terminal block for switches 1-4
12. Reverse polarity warning light (lights Red if reverse polarity is detected)
13. Thumb screw for lid fastening
14. Place holders for switch ID labels
15. Auxiliary port identifications
GET TO KNOW YOUR BANTAM
2
1
3
1 2 3 4 5 6
4
11
12
5
10
6
8
9
7
15
14
13
NOTES AND WARNINGS
Never reverse polarity on battery cables.
NEVER chassis ground the sPOD’s
negative battery cable. Always attach both
positive and negative accessory wires to
the sPOD.
Any modifications to any of the sPOD wire
harnesses will void the warranty.
Although the sPOD system is weather
proof, do not submerge in water. Do not
spray cleaner onto unit or into any
openings. Always use a soft towel or cloth
for cleaning purposes and or compressed
air to dry.
System will shut down when voltage drops
to 11.2 V (2 minute delay) and requires 12.8
V to reinitialize (start engine).
Do not tamper, open or remove any
factory-installed components; this will void
the warranty.
Do not replace 2 amp fuse with any other
rated fuse; this will void the warranty.
Do not attach any additional electrical
accessories to the battery terminals on the
Bantam; this will void the warranty.
The Bantam does not require the use of
Relays or Fuses unless the accesory
attached draws more than 30AMPS
The Bantam employs self healing circuits.
In the event of a short/overload, the circuit
will shut off. Correct the short/overload,
then cycle the switch on and off to reset.
Question and Answer IconNeed help?

Do you have a question about the Spod BANTAM and is the answer not in the manual?

Summary

Bantam Component Identification

Battery Cable Connections

Identifies positive and negative battery cable connection points and the reverse polarity warning light.

Input and Control Ports

Details input terminal block, jumper for polarity, and controller inputs (Ethernet cable).

Protection and Indicators

Describes the 2AMP fuse for circuit protection and the reverse polarity warning light.

Operational Warnings and Precautions

Polarity, Grounding, and System Limits

Warnings on polarity, chassis grounding, submerging, and system voltage shutdown limits.

Warranty and Modification Restrictions

Advisories against modifications, tampering, incorrect fuse replacement, and terminal attachments.

Installation Guide

Mounting and Cable Routing

Instructions for finding a mounting location, securing the Bantam, and routing cables.

DIP Switch Settings

Functionality of DIP Switches

Explains the purposes of DIP switches 1-6 for Bluetooth, voltage selection, and lock-out functions.

Key-On Lock-Out Activation

Details how DIP switches 3 & 4 enable Key-On Lock-Out for switches 1 & 2.

Input Terminal Block Configuration

Input Functions

Describes INPUT 1 for LVCO bypass and INPUT 2 for Key-On/Lock-Out activation.

External Device Control Inputs

Explains using INPUTS 3-10 to activate switches with external devices (3.3-24VDC).

Jumper Settings for Input Triggers

Positive vs. Ground Trigger Selection

Instructions for using the jumper to switch between positive and ground trigger inputs.

Bluetooth Pairing Procedure

App Download and Preparation

Guide to downloading the sPOD Bantam app and enabling Bluetooth on the device.

Pairing Process Steps

Detailed steps for entering pairing mode, scanning, and connecting the Bantam via Bluetooth.

Pairing Reset

Instructions on how to reset the Bluetooth pairing with all connected devices.

Spod BANTAM Specifications

General IconGeneral
ManufacturerSPOD
ModelBANTAM
WaterproofYes
CompatibilityUniversal
ConnectivityBluetooth
Water ResistanceIP67
Voltage12V
Dimensions4.5 x 3.5 x 1.5 inches
Operating Temperature-40C to +105C

Related product manuals