Installing the Pre-Filter (cont.)
34) Expose the pre-plumb and
prep to install the threaded
adapters.
35) Install a 1” threaded adapter
on the incoming water supply and
point the threads towards the
pre-filter.
38) Connect a PVC nipple to the
other end of the PVC shut off
valve.
33) Use the remaining 4 bolts to
secure the pre-filter to the
mounting bracket.
36) Point the threaded adapter
for the opposite end of the pre-
plumb towards the tank
connections.
NOTE: Plumbers tape will need
to be applied to every thread
when connecting all corrugated
pipes.
37) Connect the PVC shut off
valve onto the threaded adapter
on the incoming water supply.
39) Connect a corrugated pipe
to the PVC nipple.
40) Connect the other end of the
corrugated pipe to the inlet on
the pre-filter.
Questions? Call (800)-589-5592 10
IMPORTANT! Be sure to turn off the water main to your home
before proceeding to the next steps!