Operaon & Installaon Instrucons
UV4
Series
SpringWell - Standard Systems
System Rated Flow System Rated Flow
SPRW-UV4-2
SPRW-UV5-2
SPRW-UV6-2
2 gpm
SPRW-UV4-5C
SPRW-UV5-5C
SPRW-UV6-5C
5 gpm
SPRW-UV4-3
SPRW-UV5-3
SPRW-UV6-3
3 gpm
SPRW-UV4-10C
SPRW-UV5-10C
SPRW-UV6-10C
10 gpm
SPRW-UV4-6
SPRW-UV5-6
SPRW-UV6-6
6 gpm
SPRW-UV4-15C
SPRW-UV5-15C
SPRW-UV6-15C
15 gpm
SPRW-UV4-11
SPRW-UV5-11
SPRW-UV6-11
11 gpm
SPRW-UV4-25C
SPRW-UV5-25C
SPRW-UV6-25C
25 gpm
SPRW-UV4-15
SPRW-UV5-15
SPRW-UV6-15
15 gpm
SPRW-UV4-40C
SPRW-UV5-40C
SPRW-UV6-40C
40 gpm
SPRW-UV4-21
SPRW-UV5-21
SPRW-UV6-21
21 gpm
UV5/6
Series
UV4-C
Series
UV5/6-C
Series

Questions and Answers

  • B
    Brandon PerryJul 25, 2025
    What to do if SpringWell SPRW-UV5-15 has low UV intensity?
    • M
      Mandy SandersJul 25, 2025
      If you are experiencing low UV intensity with your SpringWell Accessories, you should remove and clean the quartz sleeve and sensor. Also, verify that your water quality meets the requirements. If necessary, add filtration. If the issue persists, replace the lamp.
  • R
    Rebecca BlevinsJul 31, 2025
    How to reset the lamp protection circuit in SpringWell SPRW-UV5-15?
    • L
      Laura PerezJul 31, 2025
      If the system detects a problem with the SpringWell Accessories lamp, try resetting the lamp protection circuit by unplugging the unit for 10 seconds. If the issue continues, replace the lamp with the correct part, which can be found on the silver label on the reactor or on the Maintenance parts screen.
  • D
    Daniel SmithAug 6, 2025
    What to do if the UV sensor is not communicating with the SpringWell Accessories system?
    • L
      Laura AllenAug 7, 2025
      If the UV sensor isn't communicating with your SpringWell Accessories system, ensure all modules are properly connected to the system and each other. Test modules individually by plugging them in one at a time and cycling power to the system. Replace any module that isn't detected when plugged directly into the controller.
  • D
    David LoveAug 13, 2025
    What to do if the module is no longer communicating with the SpringWell SPRW-UV5-15 system?
    • H
      Henry ValentineAug 13, 2025
      If a module stops communicating with the SpringWell Accessories system, make sure all modules are correctly connected to the system and to each other. You can test each module by plugging them in one at a time and restarting the system. Replace any module that the controller doesn't detect when plugged in directly.
  • S
    Shawn JacksonAug 18, 2025
    What to do if SpringWell SPRW-UV5-15 has a missing or incorrect lamp key?
    • R
      Rachel MaynardAug 18, 2025
      If you encounter a missing or incorrect lamp key with your SpringWell Accessories, ensure the lamp key (found packed with the lamp, on the connector) is installed. Unplug and reinstall the key. Verify the key part number matches the lamp on the Maintenance Parts screen.

Summary

Operation & Installation Instructions

Safety Considerations

General Safety Precautions

Covers warnings about UV light exposure, electrical hazards, and proper system usage.

Before You Begin Installation

Required Tools and Materials

Lists the tools and materials necessary for installing the UV system.

Water Quality Parameters

Assembly: Standard Output Systems

Assembly: High Output Systems

System Sizing

Location for Installation

Installation Guide

Lamp and Sleeve Removal Spacing

Diagram illustrating recommended space for safe removal of lamp and sleeve.

By-pass Assembly Diagram

Visual guide for installing a by-pass assembly for easier maintenance.

Quartz Sleeve Installation Procedure

UV Sensor Installation Procedure

Controller Connections Overview

Lamp Key and Connector Installation

System Disinfection Procedure

Cleaning the Quartz Sleeve

Cleaning the UV Sensor

Procedure for cleaning the UV sensor to maintain performance.

System Operation Overview

UV4 Controller Features

Description of the LED indicators and display for UV4 controllers.

UV5 & UV6 Controller Features

Details on the LCD screen and expandability port for UV5/UV6 controllers.

UV5;UV6 Power-up Sequence

Explanation of the controller's diagnostic start-up sequence.

UV5 Operational Screens

UV6 Operational Screens

Lamp Countdown Sequence and Warnings

System Service Reminders

UV Lamp Replacement (UV4 Systems)

UV Lamp Replacement (UV5 & UV6 Systems)

QR Codes for System Resources

System Troubleshooting

Hard Alarms Explained

Details hard alarms, their causes, and corresponding resolutions.

System Troubleshooting: Soft Alarms

Boil Water Advisory

Temperature Management Devices

Expansion Modules

Standard Output Systems Specifications

High Output Systems Specifications

Limited Warranty Statement

Limitations of Warranty

Details conditions and parameters that void the product warranty.

How to Obtain Warranty Service

Warranty Registration Process

SpringWell SPRW-UV5-15 Specifications

General IconGeneral
BrandSpringWell
ModelSPRW-UV5-15
CategoryAccessories
LanguageEnglish