TROUBLESHOOTING
TECHNICAL PARAMETERS
MODEL IM-101
PROTECTION TYPE I
POWER 115V / 60Hz
CURRENT 2.4 ~ 3.5A
REFRIGERANT R134a / 130g
NET WEIGHT 45 lbs
SIZE 17.15 x 15 x 17 inches
PROBLEM POSSIBLE CAUSE SOLUTION
symbol is flashing
Lack of Water Stop the ice maker and fill water
symbol is displayed
Ice basket is full Remove ice from ice basket
symbol is displayed
Ice shovel cannot rotate.
Check if ice-cubes are blocking the
ice-shovel. Otherwise, contact
Sunpentown
symbol flashes for 20
seconds
Ice-full detecting sensor is
faulty
Please contact Sunpentown
The ice making cycle is too
long
Stop the ice maker and restart after
the ice blocks melt. Select the small
ice size Ice cubes stick together.
Water temperature in
reservoir is too low
Change the water in the reservoir.
Use water between 45°F ~ 90°F
Ambient temperature or
water temperature in
reservoir is too high.
Ambient temperature should be
below 90°F and use colder water
Refrigerant liquid leakage. Contact Sunpentown
Ice making cycle is normal
but no ice is made.
Pipe in the cooling system is
blocked.
Contact Sunpentown