1
HPRP Series
Refrigerated Type Compressed Air Dryers
Models: HPRP100, HPRP125, HPRP150, HPRP200, HPRP250, HPRP300, HPRP400, HPRP500, HPRP600, HPRP750
FORM NO.: 5002730 REVISION: 01/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.
INSTRUCTION MANUAL

Questions and Answers

  • O
    Omar SantosAug 9, 2025
    What to do if my SPX Hankison HPRP750 Dehumidifier refrigeration system is not functioning properly?
    • J
      Jessica TuckerAug 9, 2025
      If the power light is off, ensure the unit is receiving power. Also, close the disconnect switch and check for continuity. An electrician should inspect the electrical connections. Verify the unit operates within the minimum and maximum temperature ranges. Clean the condenser and ensure there's adequate airflow.
  • M
    michaelandersonAug 19, 2025
    Why is there high pressure drop across my SPX Dehumidifier?
    • J
      Jesus Sutton IVAug 19, 2025
      A high-pressure drop could be due to the flow rate. Check the flow rate and replace the filter element.
  • N
    Nicole Cobb DVMAug 28, 2025
    What to do if there is water downstream of my SPX Hankison HPRP750 Dehumidifier?
    • J
      Joel GrimesAug 28, 2025
      To address water downstream, blow out the system with dry air. Also, check the valve positions and ensure correct connections. Insulate or heat trace air lines exposed to low ambients, or use dry air to lower the dew point. Consider installing a separator ahead of the dryer.

Summary

General Safety Information

Pressurized Devices Safety

Safety precautions related to pressure-containing components on the dryer unit.

Electrical Safety Guidelines

Guidelines for safe electrical installation, wiring, and service procedures.

Receiving, Moving, and Unpacking

Installation Procedures

Dryer Operation

Start-up Procedures

Step-by-step guide for starting up the dryer, including control panel operations.

Fault Indicators and Types

Explains common faults, their indicators, and potential causes.

Maintenance Procedures

Wiring Diagrams

Model 100 (120;230 VAC)

Electrical schematic for the Model 100, 120/230 VAC.

Models 125-150 (120;230 VAC)

Electrical schematic for the Models 125-150, 120/230 VAC.

Models 200-600 (460 VAC) - Sheet 1 of 2

First part of the electrical schematic for Models 200-600 (460 VAC).

Models 200-600 (460 VAC) - Sheet 2 of 2

Second part of the electrical schematic for Models 200-600 (460 VAC).

Troubleshooting Guide (Models 100-150)

Refrigeration System Malfunctions

Diagnosing and resolving issues with the refrigeration compressor.

Troubleshooting Guide (Models 200-750)

Water Downstream

Symptoms and causes for water appearing downstream of the dryer.

Checkpoint Faults

Diagnosing faults indicated by alarm/service lights and display alerts.

Specific Fault Resolution

Detailed steps for resolving common faults like low pressure, high temperature.

Warranty Information

SPX Hankison HPRP750 Specifications

General IconGeneral
BrandSPX
ModelHankison HPRP750
CategoryDehumidifier
LanguageEnglish

Related product manuals