EasyManua.ls Logo

ST VL6180X - VL6180 X Range Ignore Function

ST VL6180X
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DocID026571 Rev 1 17/27
AN4545 Cover glass
27
5.1.2 Range ignore
The range ignore function in VL6180X can be enabled by setting bit 1 of
SYSRANGE__RANGE_CHECK_ENABLES {0x2d}. If enabled, the ignore threshold must
be specified.
We recommend setting the ignore threshold to at least 1.2x cross talk.
e.g. SYSRANGE__RANGE_IGNORE_THRESHOLD {0x26} = cross talk (Mcps) x 1.2
A range ignore error will be flagged if the return signal rate is less than the ignore threshold.

Related product manuals