5.1.2 Range ignore
The range ignore function in VL6180X can be enabled by setting bit 1 of
SYSRANGE__RANGE_CHECK_ENABLES {0x2d}. If enabled, the ignore threshold must
be specified.
We recommend setting the ignore threshold to at least 1.2x cross talk.
e.g. SYSRANGE__RANGE_IGNORE_THRESHOLD {0x26} = cross talk (Mcps) x 1.2