DURA-GLAS
TM
CENTRIFUGAL PUMPS
WITH INTEGRAL TRAP
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
P2R and P2RA Series MODELS
HP P2R Series P2RA Series
1/2 – P2RA52C3-119
3/4 P2R52D3-124 P2RA52D3-120
1 P2R52E3-125 P2RA52E3-124
1-1/2 P2R52F3-126 P2RA52F3-125
2 P2R52G3-122 P2RA52G3-126
2-1/2 P2RAA52G3-122
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
North America: 800-752-0183, FAX 800-582-2217
International: 414-728-5551, FAX: 414-728-4461, TELEX: ITT 4970245
Oxnard, CA • Union City, TN • Delavan, WI • Mississauga, Ont.
© 1996, Sta-Rite Industries, Inc. Printed in U.S.A. S138 (Rev. 11/18/96)
This manual should be furnished to
the end user of this pump; its use
will reduce service calls and chance
of injury and will lengthen pump life.

Questions and Answers

  • S
    Stacey CarterJul 26, 2025
    Why is my STA-RITE Swimming Pool Pump not pumping or has reduced capacity?
    • L
      Laura DrakeJul 26, 2025
      Several factors can cause your STA-RITE Swimming Pool Pump to fail to pump or experience reduced capacity. It could be due to suction leaks, a clogged pipe, trap, or impeller, a worn impeller, electrical issues, or mechanical troubles. Ensure the pump is primed and the volute and trap are full. Check for suction leaks in the piping and ensure the suction pipe inlet is well below the water level. Also, inspect the suction trap gasket and replace it if defective. Make sure the suction trap is not clogged; if it is, clean the trap and strainer. Check the impeller for clogging.
  • Z
    Zachary KingJul 30, 2025
    What to do if my STA-RITE DURA-GLAS is running too slowly?
    • R
      Robert JonesJul 30, 2025
      If your STA-RITE Swimming Pool Pump is running too slowly, it may be an electrical issue. Check the voltage at the motor terminals and at the meter while the pump is running. If the voltage is low, refer to the wiring instructions or consult your power company. Also, check for any loose connections and tighten them.
  • M
    Melissa MooreAug 3, 2025
    What should I do if my STA-RITE DURA-GLAS gets too hot?
    • R
      Rodney ClarkeAug 3, 2025
      If your STA-RITE Swimming Pool Pump is overheating, there are several things you can do: * Increase ventilation around the pump. * Reduce the ambient temperature in the area where the pump is located. * Ensure that all electrical connections are tight.
  • S
    Sylvia NortonAug 8, 2025
    What to do if my STA-RITE DURA-GLAS suction lift is too high?
    • J
      jriceAug 8, 2025
      If the suction lift of your STA-RITE Swimming Pool Pump is too high (15 to 25 feet reducing performance, or over 25 feet preventing pumping), move the pump closer (vertically) to the water source and ensure the suction pipe is adequately sized.
  • H
    Heather HenryAug 12, 2025
    What to do if my STA-RITE DURA-GLAS Swimming Pool Pump has low line voltage?
    • T
      Theodore Turner MDAug 12, 2025
      If the line voltage for your STA-RITE Swimming Pool Pump is less than 90% or more than 110% of the rated voltage, consult a licensed electrician.
  • A
    Annette ClarkAug 16, 2025
    How to fix mechanical noise in my STA-RITE DURA-GLAS?
    • J
      Jeanne LeeAug 16, 2025
      To reduce mechanical noise in your STA-RITE Swimming Pool Pump, ensure the suction and discharge piping are adequately supported. Do not mount the pump on a wooden platform; securely mount it on a concrete platform for the quietest performance.
  • L
    Lisa ArnoldAug 20, 2025
    What to do if my STA-RITE DURA-GLAS Swimming Pool Pump needs a higher head?
    • V
      Victor HarrisonAug 21, 2025
      If your STA-RITE Swimming Pool Pump is trying to push too high a column of water, a "higher head" pump is needed.

Summary

Safety Instructions

Understanding Safety Symbols

Explains safety alert symbols and important warnings for safe operation and installation.

Installation Guidelines

Electrical Specifications

Grounding, Bonding, and Wiring

Procedures for safe grounding, bonding, and circuit wiring, including GFCI protection.

Pump Operation and Storage

Pump Service and Maintenance

Shaft Seal Replacement

Procedures for disassembling the pump and replacing the shaft seal for maintenance.

Troubleshooting Common Issues

Suction and Priming Problems

Addresses issues related to suction leaks, lost prime, and low performance.

Clogging and Wear Issues

Diagnoses issues caused by clogged pipes, traps, impellers, or worn impellers.

Electrical and Mechanical Faults

Covers troubleshooting for electrical problems, noise, and mechanical issues.

STA-RITE DURA-GLAS Specifications

General IconGeneral
BrandSTA-RITE
ModelDURA-GLAS
CategorySwimming Pool Pump