EasyManua.ls Logo

STA-RITE MPFA6E-146L - Electrical System Issues; Pump Speed and Temperature Diagnosis; Mechanical Troubleshooting and Noise; Piping Support and Mounting Impact

STA-RITE MPFA6E-146L
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Electrical:
10. Pump may be running too slowly; check voltage at
motor terminals and at meter while pump is running.
If low, see wiring instructions or consult power
company. Check for loose connections.
11. Pump may be too hot.
A. Check line voltage; if less than 90% or more
than 110% of rated voltage consult a licensed
electrician.
B. Increase ventilation.
C. Reduce ambient temperature.
D. Tighten any loose connections.
MECHANICAL TROUBLES AND NOISE
1. If suction and discharge piping are not adequately
supported, pump assembly will be strained. See
“Installation”, Page 3.
2. Do not mount pump on a wooden platform!
Securely mount on concrete platform for quietest
performance.
Hazardous voltage.
Can shock, burn,
or cause death.
Disconnect power
before working
on pump or motor.

Related product manuals