8
Wiring
Pump must be permanently connected to circuit. See Figures 4A, 4B and 4C
for wiring connection diagrams. See Table I, Page 9, for correct wire and cir-
cuit breaker sizes for the pump alone. If other lights or appliances are also on
the same circuit, be sure to add their amp loads to pump amp load before fig-
uring wire and circuit breaker sizes. (If unsure how to do this or if this is con-
fusing, consult a licensed electrician.) Use the load circuit breaker as the
master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-
circuit to ground and disconnect power before it becomes dangerous to pool
users. For size of GFCI required and test procedures for GFCI, see manufac-
turer’s instruction.
In case of power outage, check GFCI for tripping (which will prevent normal
pump operation). Reset if necessary.
Power Supply for
Optional Timer.
Low Spd
High Spd
Circuit
Protector
Remote
SPDT
Switch
Ground (Green)
Common
If using timer, Connect
Timer Motor to Low Speed Only
Minimum switch and timer amp rating must equal Branch Fuse
Rating given in "Recommended Fusing and Wiring Data" table.
A
B
L2
L1
230
Volt
Lines
Back of
motor
with
Terminal
Board
1168 0794
Figure 4C – Wiring hook-up diagram, two speed motors.
A
B
L2
L1
White
230
Volt
Lines
Blue
SINGLE
VOLTAGE
MOTORS
A
B
L2
L1
White w/
Black
Tracer
Black
230
Volt
Lines
DUAL
VOLTAGE
MOTORS
469 0194
A
B
L2
L1
White w/
Black
Tracer
Black
115
Volt
Lines
Motor Terminal Board Connections
Figure 4A – Wiring connections
to terminal board with spade
connectors (single speed, single
phase motors).
Figure 4B – Wiring connections for
plug-in type terminal board (single
speed, single phase motors).
230 Volt to 115 Volt Conversion,
Plug-in Type:
Pull plug
straight
out from
terminal
board.
1.
1.
A
L1
230
Volts
115
Volts
2.
2.
Plug in again
with arrow
on plug
pointing to
'115 Volts'.
A
L1
230
Volts
115
Volts
Ground
Screw
3187 1199SK