67$&. 67 6HULHV 5RDG &DU 'LVSOD\ 6\VWHPV &KDSWHU  7URXEOHVKRRWLQJ
No. Symptom Possible Cause Remedy Notes
26 No alarms for
water, oil or fuel
(temperatures and
pressures) being
displayed
All the alarms have
been switched off
Switch on the
required alarms
Alarms only
operate when
the engine is
running above
the RPM gate
value.
The engine RPM
gate value is set
too high
Reset the RPM
gate to a lower
value.
27 Display and alarm
light flash when
the engine is
running
Intermittent alarm
caused by a
parameter with its
alarm level set too
close to the normal
operating value
Either change the
value for the alarm
or turn the alarm off
Press Switch 2
to see which
sensor is
causing the
alarm
28 Fuel level reading
does not change
1. Fuel sender
wiring not
connected
correctly
2. Faulty fuel
sender
3. Fuel sender not
suitable for use
with ST8130
Display System
1. Check wiring
2. Check fuel
sender
3. Check with
your Stack
dealer for
suitable
alternative
If there is no
reading from
the fuel sender,
remove the fuel
sender unit
from the tank,
earth it to the
vehicle with a
clip lead and
move it by hand
to verify that the
4. Fuel sender not
calibrated
See Chapter 4 for
information on how
to calibrate the fuel
sender.
voltage reading
on the red lead
changes. The
voltage on the
red lead should
range from 0V
to 5V.