Troubleshooting
Trouble Cause Remedy
Does not start.
Starts, but
immedi
ately stops.
(1) Power failure
(1)-(3) Contact electric power company
and devise countermeasures
(2) Large discrepancy between power source and
voltage
(3) Significant drop in voltage
(4) Motor phase malfunction
(4) Inspect electric circuit
(5) Electric circuit connection faulty
(5) Correct wiring
(6) Faulty connection of control circuit
(6) Inspect connections and magnetic coil
(7) Fuses is blown
(7) Check circuit then replace fuse
(8) Faulty magnetic switch
(8) Replace with correct one
(9) Water is not at level indicated by Float
(9) Raise water level
(10) Float is not in appropriate level
(10) Adjust the position of float
( 11) Float is not effective
(11) Repair or replace
(12) Short circuit breaker is functioning
(12) Repair location of short circuit
(13) Foreign matter clogging pump
(13) Remove foreign matter
(14) Motor burned out
(14) Repair or replace
(15) Motor bearing broken
( 15) Repair or replace
Operates, but stops
after a while.
(1) Prolonged dry operation has activated motor
protector and caused pump to stop
(1) Raise water level to C.W.L
(2) High liquid temperature has activated motor protector
and caused pump to stop
(2) Lower liquid temperature
(3) Reverse rotation
(3) Correct rotation
Does not pump. In-
adequate volume.
(1) Reverse rotation
(1) Correct rotation (see Operation)
(2) Significant drop in voltage
(2) Contact electric power company
(3) Operating a 60Hz pump with 50Hz
(3) Check nameplate
(4) Discharge head is high
(4) Recalculate and adjust
(5) Laroe piping loss
(5) Recalculate and adjust
(6) Low operating water level causes air suction
(6) Raise water level or lower pump
(7) Leaking from discharge piping
(7) Inspect, repair
(8) Clogging of discharge piping
(8) Remove foreign matter
(9) Foreign matter in suction inlet
(9) Remove foreign matter
(10) Foreign matter cooling pump
(10) Remove foreign matter
(11) Worn impeller
(11) Replace impeller
Over current
(1) Unbalanced current and voltage
(1) Contact electric power company
(2) Significant voltage drop
(2) Contact electric power company and
devise countermeasure
(3) Motor phase malfunction
(3) Inspect connections and magnetic
switch
(4) Operating 50Hz pump on 60Hz
(4) Check nameplate
(5) Reverse rotation
(5)
Correct rotation (see Operation2)
(6) Low head. Excessive volume of water
(6) Replace pump with high head pump
(7) Foreign matter clogging pump
(7) Remove foreign matter
(8) Motor bearing is worn out or damaged
(8) Replace bearing
Pump vibrates; ex-
cessive operating
noise.
(1) Reverse rotation
(1) Correct rotation
(2) Pump clogged with foreign matter
(2) Disassemble and remove foreign
matter
(3) Piping resonates
(3) Improve piping
(4) Strainer is closed too far
(4) Open strainer

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stancor SE Series and is the answer not in the manual?

Stancor SE Series Specifications

General IconGeneral
BrandStancor
ModelSE Series
CategoryWater Pump
LanguageEnglish

Related product manuals