Trouble Cause Remedy
Starts, but
immedi
ately stops.
(1)-(3) Contact electric power company
and devise countermeasures
(2) Large discrepancy between power source and
voltage
(3) Significant drop in voltage
(4) Motor phase malfunction
(4) Inspect electric circuit
(5) Electric circuit connection faulty
(6) Faulty connection of control circuit
(6) Inspect connections and magnetic coil
(7) Check circuit then replace fuse
(8) Faulty magnetic switch
(8) Replace with correct one
(9) Water is not at level indicated by Float
(10) Float is not in appropriate level
(10) Adjust the position of float
( 11) Float is not effective
(12) Short circuit breaker is functioning
(12) Repair location of short circuit
(13) Foreign matter clogging pump
(13) Remove foreign matter
(15) Motor bearing broken
after a while.
(1) Prolonged dry operation has activated motor
protector and caused pump to stop
(1) Raise water level to C.W.L
(2) High liquid temperature has activated motor protector
and caused pump to stop
(2) Lower liquid temperature
adequate volume.
(1) Correct rotation (see Operation)
(2) Significant drop in voltage
(2) Contact electric power company
(3) Operating a 60Hz pump with 50Hz
(4) Discharge head is high
(4) Recalculate and adjust
(5) Recalculate and adjust
(6) Low operating water level causes air suction
(6) Raise water level or lower pump
(7) Leaking from discharge piping
(8) Clogging of discharge piping
(8) Remove foreign matter
(9) Foreign matter in suction inlet
(9) Remove foreign matter
(10) Foreign matter cooling pump
(10) Remove foreign matter
(1) Unbalanced current and voltage
(1) Contact electric power company
(2) Significant voltage drop
(2) Contact electric power company and
devise countermeasure
(3) Motor phase malfunction
(3) Inspect connections and magnetic
switch
(4) Operating 50Hz pump on 60Hz
(5)
Correct rotation (see Operation2)
(6) Low head. Excessive volume of water
(6) Replace pump with high head pump
(7) Foreign matter clogging pump
(7) Remove foreign matter
(8) Motor bearing is worn out or damaged
cessive operating
noise.
(2) Pump clogged with foreign matter
(2) Disassemble and remove foreign
matter
(4) Strainer is closed too far