If your compressor does not start
• Check that you have plugged the power lead into a standard
240V 10Amp power point and turned the switch ON.
• Check that you have turned the air compressor ON/OFF switch
ON.
• The air tank may be full. Use your air tool and the air
compressor should start when the pressure decreases to 85PSI.
If your compressor does not build up pressure
• Check that the tank drain tap is sealed.
• Check that the air fitting is not leaking. If leaking replace.
If your compressor smells like burnt oil
• Using beyond the 75% duty cycle, allow to cool for 30 minutes
before reusing this air compressor.
Call SMG for your closest centre,
Aust. 1300 660 457 N.Z. 0800 474 876.
MAINTENANCE
Daily: Before Use
1. Seal the tank drain tap, see page 16, Pic. 11 & 12.
2. Check safety valve operation, see page 15, Pic. 9.
After Use
1. Open the tank drain tap, see page 16, Pic. 11 & 12.
2. Wipe down the air compressor.
3. Store safely and securely.
TROUBLE SHOOTING