11. Troubleshooting
Fault Cause 2EMEDY
Engine does not start Oil shortage cut-out has not responded
Spark plug fouled
No fuel
Battery voltage too low
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / check the petrol cock
Charge the battery
Generator has too little or no voltage Controller or capacitor defective
Overload cut-off has triggered
!IRÏlLTERÏDIRTY
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
#LEANÏORÏREPLACEÏTHEÏlLTER
11.
T
rou
bl
es
h
oot
i
n
g
12. Maintenance schedule
Regular service period
Perform at every indicated month
or operating hour interval,
ÏÏÏWHICHEVERÏCOMESÏlRST
ITEM
Each
use
First
month
or
20 Hrs.
Every
3
months
or
50 Hrs.
Every
6
months
or
100 Hrs.
Every
year
or
200 Hrs.
Engine oil Check level
Change
O
OO
Air cleaner Check
Clean
O
O (1)
Spark plug Check-adjust
Replace
O
O
Spark arrester Clean
O
Valve clearance Check-adjust
O (2)
Combustion chamber Clean After every 300 hrs. (2)
&UELÏTANKÏANDÏlLTERÏÏÏÏÏÏ#LEAN
O (2)
Fuel tube Check Every 2 years (Replace if necessary) (2)
Remark:
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, Refer to the manual for service procedures.
Failure to follow this maintenance schedule could result in non-warrantable failures.