EasyManua.ls Logo

Stanley Fatmax FMHT77419 - GENERAL SPECIFICATION; SPECIFICATIONS; DC Voltage Specifications

Stanley Fatmax FMHT77419
174 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Ω, kΩ, MΩ Resistance unit
Ω: Ohm; kΩ: Kilohm; MΩ: Megohm; 1MΩ =10
3
=10
6
Ω
nF, ɥF Capacitance unit
nF: Nanofarad; ɥF: Microfarad
1F=10
6
ɥF=10
9
nF=10
12
pF
Hz, kHz, MHz Frequency unit
Hz: Hertz; kHz: Kilohertz; MHz: Megahertz
1MHz=10
3
kHz=10
6
Hz
% Unit of duty cycle
%: Percent
GENERAL SPECIFICATION
Display: 3 3/4-digit LCD, with a max. reading 3999
Overrange Indication: "OL" shown on the display
Negative Polarity Indication: negative sign "
" shown on the
display automatically
Sampling Rate: 2 -3 times/sec
Operating Environment: 0°C ~ 40°C, < 75%RH
Temperature Coefficient: 0.2 x (specified accuracy)/°C (< 18°C or
> 28°C)
Storage Environment: - 10°C ~ 50°C, <85%RH
Operating Altitude: 0 to 2000 meters
Battery: 9V, 6F22 or equivalent, 1 piece
Low Battery Indication: "
" shown on the display
Size: 217x100x49mm
Weight: about 500g (including battery)
IP: 51
SPECIFICATIONS
Accuracy is specified for a period of one year after calibration and at
18°C to 28°C, with relative humidity < 75%.
Except where specified, accuracy is specified from 8% to 100% of
range.
DC Voltage
Range Resolution Accuracy
400mV 0.1mV ± (1.0% + 5)
4V 0.001V
± (0.8% + 3) 40V 0.01V
400V 0.1V
600V 1V ± (1% + 5)
Input Impedance: the range 400mV: >1000MΩ / the other
ranges: 10
Overload Protection: 600V DC/AC rms