2
ENGLISH
English (original instructions)
WARNING: To reduce the risk of injury, read and
understand these safety warnings and instructions before
using the light. Keep these instructions with the light for
future reference. If you have questions or comments,
contactus.
WARNING: Using this appliance in an environment
with a strong radiated radio-frequency elec tromagnetic
field (approximately 3V/m), may Influence its measuring
accuracy. The measuring result can be strongly deviating
from the actual value. Read, understand and follow
Safety.Rules and Operating Instructions of the manual
beforeusing.
WARNING: BE EXTREMELY CAREFUL IN THE USE OF THIS
DEVICE. Improper use of this device can result in Injury or
death. Follow all safeguards sug gested in this manual in
addition to the normal safety precautions used in working
with electrical circuits. DO NOT service this device if you
are not qualified to doso.
The normal function of the product may be disturbed by strong
Electro-Magnetic Interference. If so, simply reset the product to
resume normal operation by following the instruction manual.
In case the function could not resume, please use the product in
otherlocation.
Battery Installation
WARNING:
• To avoid electric shock, do not operate the meter until
the battery cover is in place and fastened securely.
• The measurement must be done only with cap on the
probetip.
1. Open the battery door (end cap) by gently prying up/out at
the pocket clip using smallscrewdriver.
2. Insert one A23S Type alkaline battery batteries
(observepolarity).
3. Replace the battery door
NOTE: If your meter does not work properly, check the battery
to make sure if it is still good and that it is properlyinserted.
Functions
Sound and lightinstructions.
Adjustable sensitivity, Setting the defaultsensitivity.
Low batterydetection.
Auto power off.
Description (Fig. A)
WARNING: Never modify the power tool or any part of it.
Damage or personal injury couldresult.
1
Test lead
2
Up
3
Down
4
Power
Markings on Tool
The following pictograms are shown on the tool:
Important safety information, refer to the operating
manual
Double insulation
Earth ground
Complies with European (EU) safety standards
CONFORMS TO UL STD. 61010-1, 61010-2-030,
CERTIFIED TO CSA STD C22. 2 NO. 61010-1,
61010-2-030
FMHT82567-0
AC voltage range 20~1000 V AC (50/500 Hz)
Metal detection distance <20 mm (ln direct proportion to testing area)
Safety standard EN61010-1/CATII 1000V CATIII 600V
Operating temperature 14~122 °F (-10~50 °C)
Storage temperature -4~140 °F (-20~60 °C)
Humidity <85% RH
Battery 1x12 V (A23S Type) alkaline battery
Size/Weight 157x24x20 mm/42 g
Congratulations!
You have chosen a STANLEY FATMAX tool. Years of experience,
thorough product development and innovation make
STANLEYFATMAX one of the most reliable partners for
professional power toolusers.
Technical Data
NO CONTACT VOLTAGE AND METAL DETECTOR
FMHT82567-0