Models: G5000S & G8000S 
Controls 
 
Recoil Starter 
 
To start the engine, pull the starter grip lightly until resistance is felt, 
then pull briskly. 
 
NOTICE: 
Do not allow the starter grip to snap back against the engine. Return it 
gently to prevent damage to the starter.  
 
The recoil starter is used to start the engine if the generator is not 
equipped with a 12 volt battery to operate the starter motor, or if the 
battery does not contain adequate charge to operate the starter motor. 
Fuel Valve Lever 
 
The fuel valve is lo-
cated between the fuel 
tank and carburetor. 
When the valve lever is 
in the ON position, fuel 
is allowed to flow from 
the fuel tank to the 
carburetor. Be sure to 
return the fuel valve 
lever to the OFF posi-
tion after stopping the 
engine. 
Choke Rod 
 
The choke is used to 
provide an enriched 
fuel mixture when 
starting a cold engine. 
It can be opened and 
closed by operating 
the choke rod manu-
ally. Pull the rod out 
toward CLOSED to 
enrich the mixture for 
cold starting.  Open 
once the engine is 
running. 
WARNING 
The engine was shipped without engine oil.  DO NOT START THE 
ENGINE WITHOUT FILLING THE ENGINE WITH OIL.  Use SAE 10W-
30 for normal conditions and SAE 5W-30 when the ambient tem-
perature is below 32° F. 
Engine Switch 
To start and stop the engine. 
 
Engine ON / OFF / Start Switch 
(electric start shown) 
 
Turn clockwise 
to turn fuel valve 
on. 
O
F
F
 
ON
 
Oil Alert System 
 
The Oil Alert system is designed to prevent engine damage caused by 
an insufficient amount of oil in the crankcase. Before the oil level in the 
crankcase can fall below a safe limit, the Oil Alert system will automati-
cally stop the engine (the engine switch will remain in the ON position). 
The Oil Alert system should not take the place of checking the oil level 
before each use. If the engine stops and will not restart, check the 
engine oil level (see page 14) before troubleshooting in other areas. 
Ground Terminal 
 
The generator ground terminal is connected to the 
frame of the generator, the metal non-current-
carrying parts of the generator, and the ground 
terminals of each receptacle. 
 
 
 
 
Before using the ground terminal, consult a qualified electrician, 
electrical inspector or local agency having jurisdiction for local 
codes or ordinances that apply to the intended use of the genera-
tor. 
WARNING 
RECOIL STARTER 
STARTER GRIP 
NOTE:  SYSTEM GROUND IS CONNECTED TO THE AC NEUTRAL ON 
THIS GENERATOR.  CONSULT AN ELECTRICIAN WHEN CONNECT-
ING THIS GENERATOR TO YOUR HOME OR BUSINESS ELECTRICAL 
PANEL TO ENSURE GROUNDING MEETS THE LOCAL ELECTRICAL 
CODE