TECHNICAL DATA
MANUFACTURED SMOKELESS
FUEL
WOOD
Max: (kW)
Nominal: (kW)
Room Water Total
4.7kW 12.5 kW 17.2
3.6kW 12.3kW 15.9
Room Water Total
3.8 kW 8 kW 11.8
3.5 kW 7.4kW 10.9
Typical refuelling intervals to obtain nominal
outputs:
MSF 2 hours WOOD .90 hrs
Flue Gas Mass Flow: MSF 9.9 g/s WOOD 10 g/s
Flue Gas Mass at nominal output: 372
o
C 258
o
C
Gross Weight: 200 kgs
Flue Outlet: 150mm
Flue Draught: 12 Pa
Boiler Tappings: 1” BSP
Max Water Pressure: 2 Bar
Efficiency: 76.3 % 76.8%
Model
Energy
Efficiency
Class
Heat Output
to Room
Heat Output
to Water
Energy
Efficiency
Index
Preferred
Fuel
Nominal
Heat
Output
Net Efficiency
Lismore
HPB SF
Stove
A 3.5 7.4 102.36 Wood 10.9 76.8
LIGHTING
Before lighting the stove check with the installer, that the installation work and commissioning checks
described previously have been carried out correctly and the chimney has been swept clean, is sound and
free from any obstructions. As part of the stove commissioning and handover the installer should demon-
strate how to operate the stove correctly.