Notes
These�figures�(*)�are�for�readers�powered�from�the�controller.�The�cable
distances�can�be�increased�to�1650ft�/�500m�by�locally�powering�the�readers.
Locally�powered�readers�must�be�connected�to�a�UL�603�power�limited�Class�2
supply�for�US,�or�a�ULC�S318�power�limited�Class�2�supply�for�Canada.
If�you�use�22AWG/�0.34mm²�cables,�twist�the�wires�and�double�them�over
before�inserting�them�in�the�crimps.
Maximum�cable�distances�will�be�less�for�readers�which�have�been�set�to�give
Wiegand�output.
Specification
Card Token Power Current
<�2.0in�/�50mm <�1.1in�/�30mm 12V�—�+24V <�100mA
Temperature
Operating Storage
-40°C�—�+66°C�/�-40°F�—�+151°F -40°C�—�+66°C�/�-40°F�—�+151°F
Humidity
Operating�for�24�hours
10-85%�RH�@�30±2°C�/�85±4°F Tested�at�93%�for�ULC�S319.
Ingress�Protection
IP65�after�installation.�Installer�must�adequately�seal�any�connections�made.