26 • ENGLISH
* Maximum initial battery pack voltage
(measured without a workload) is 20 volts.
Nominal voltage is 18V.
CHARGING TIME
SB20C (1,3Ah) + SC201 (1A) = Charge time 75 min.
SB20C (1,3Ah) + SC202 (2A) = Charge time 45 min.
SB20D (2,0Ah) + SC202 (2A) = Charge time 60 min.
TROUBLE SHOOTING
PROBLEMA CAUSA POSIBLE SOLUCIÓN POSIBLE
Unit will not start.
Battery pack not installed properly. Check battery pack installation.
Battery pack not charged.
Check battery pack charging
requirements.
Unit starts immediately upon inserting
battery.
The switch has been left in the “On”
position.
The switch must be moved to “Off
to prevent the tool from immediately
starting when battery is inserted
Battery pack will not charge
Battery pack not inserted into charger.
Insert battery pack into charger until
LED lights.
Charger not plugged tin.
Plug charger into a working out let.
Refer to “Important charging notes”
for more details.
Surrounding air temperature too hot
or too cold.
Move charger and battery pack to a
surrounding air temperature of above
40°F (4,5°C) or below 105°F +40,5°C).
Unit shuts off abruptly.
Battery pack has reached its maximum
thermal limit.
Allow battery pack to cool down.
Out of charge. (To maximize the life
of the battery pack it is designed to
shut off abruptly when the charge is
depleted).
Place on charger and allow to charge.