EasyManua.ls Logo

Star HSPJ100 - User Manual

Star HSPJ100
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
© 2015 Star Water Systems. All rights reserved.
STOP
Questions, problems, missing
parts? Before returning to your
retailer, call our customer service
department at 1-800-742-5044,
7:30 a.m. - 5 p.m., EST, Monday
- Friday.
Description
This pump is designed to sprinkle lawns and small
gardens from lakes, ponds, or rivers, empty or fill
stock tanks, remove standing water from flooded
areas, transfer water or boost water pressure.
Flammable liquids such as gasoline, chemicals or
corrosive liquids should never be used with this pump.
Safety Guidelines
This manual contains information that is very
important to know and understand. This information
is provided for SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this information,
observe the following symbols.
Danger indicates an imminently
hazardous situation which, if not avoided, will result
in death or serious injury.
Warning indicates a potentially
hazardous situation which, if not avoided, could result
in death or serious injury.
Caution indicates a potentially
hazardous situation, which, if not avoided, may result
in minor or moderate injury.
NOTE: Indicates important information, that if not
followed, may cause damage to equipment.
General Safety Information
1. Read these rules and instructions carefully. Failure
to follow these instructions could cause serious
bodily injury and/or property damage.
This pump is non-submersible.
This product contains chemicals
known to the State of California to cause cancer and
birth defects or other reproductive harm.
Pump only clear water.
Do not pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc. Do
not use in a flammable and/or explosive
atmosphere. Personal injury and/or property damage
could result.
NOTE: This pump is not designed to handle salt water,
brine, laundry discharge or any other application
which may contain caustic chemicals and/or foreign
materials. Pump damage could occur if used in these
applications and will void warranty.
All wiring must be
performed by a qualified electrician. The
pump must be installed in compliance with
all local and national codes.
2. Connect this product to a grounded circuit
equipped with a ground fault circuit interruptor
(GFCI) device.
3. Before installing this product, have the electrical
circuit checked by an electrician to ensure proper
grounding.
4.
BE CERTAIN the pump power source
is disconnected before installing or
servicing pump.
5. Be sure the water source and piping are clear of
sand, dirt and scale. Debris will clog pump and
void warranty.
6. Failure to protect pump and piping from freezing
could cause severe damage and will void the
warranty.
7. Do not run pump dry.
Installation
PUMPING FROM LAKES, PONDS OR SMALL STREAMS
1. Locate pump as close as possible to the water
source, keeping the vertical distance from the
water to pump as small as possible. Place pump
on level support. Protect against flooding and
excessive moisture.
2. Long lengths of pipe or hose and use of many
fittings will reduce pump flow. Use the smallest
number of fittings and shortest possible length of
pipe or hose.
4. Connect inlet pipe or hose to pump. The inlet
connection is designed for 1” NPT thread. Rigid
PORTABLE LAWN
SPRINKLER AND UTILITY
PUMP
SW1015 1215
Supersedes
NEW
IL1856
On/o
switch
Question and Answer IconNeed help?

Do you have a question about the Star HSPJ100 and is the answer not in the manual?

Summary

Product Description

Safety Guidelines and Information

General Safety Information

Provides essential safety rules and warnings to prevent injury and equipment damage, including danger and warning symbols.

Pump Installation

Pumping from Lakes, Ponds, or Small Streams

Instructions for installing the pump to draw water from natural sources, emphasizing proximity and pipe setup.

Boosting Water Pressure

Steps for connecting the pump to boost water pressure, including inlet and outlet connections.

Pump Operation

Maintenance and Winter Draining

Draining for Winter

Guidance on how to properly drain the pump and piping to protect against freezing temperatures.

Troubleshooting

Warranty Information

Replacement Parts

Overview

This document describes the Portable Lawn Sprinkler and Utility Pump, Model HSPJ100, designed for various water transfer applications.

Function Description

The pump is designed to sprinkle lawns and small gardens from lakes, ponds, or rivers. It can also be used to empty or fill stock tanks, remove standing water from flooded areas, transfer water, or boost water pressure. It is a non-submersible pump.

Important Technical Specifications

  • Power Supply: 115 volts, 60 Hz
  • Individual Branch Circuit Required: 15 Amp minimum
  • Maximum Water Temperature: 77°F (25°C)
  • Discharge Connection: 1 inch NPT thread
  • Suction Connection: 1 inch NPT thread
  • Water Depth Rating: Maximum of 25 feet
  • Discharge Pressure vs. Flow Rate:
    • 5 PSI: 800 Gallons per Hour
    • 10 PSI: 700 Gallons per Hour
    • 17 PSI: 600 Gallons per Hour
    • 25 PSI: 500 Gallons per Hour
    • 30 PSI: 400 Gallons per Hour
    • 40 PSI: 200 Gallons per Hour
    • 50 ft.: 100 Gallons per Hour

Usage Features

  • Water Compatibility: Designed to pump only clear water. It is explicitly stated not to pump flammable or explosive fluids (such as gasoline, fuel oil, kerosene), caustic chemicals, salt water, brine, laundry discharge, or any other application containing foreign materials. Using the pump with incompatible liquids will void the warranty and can cause personal injury or property damage.
  • Electrical Safety: The pump is supplied with a grounding conductor and a grounding-type attachment plug. It must be connected to a grounded circuit equipped with a Ground Fault Circuit Interrupter (GFCI) device. All wiring must be performed by a qualified electrician in compliance with local and national codes. The round grounding prong on the power cord must never be cut off, as this makes the pump unsafe and voids the warranty.
  • Installation for Pumping from Lakes, Ponds, or Small Streams:
    • Locate the pump as close as possible to the water source, minimizing the vertical distance from the water to the pump.
    • Place the pump on a level support and protect it from flooding and excessive moisture.
    • Minimize pipe/hose length and the number of fittings to maximize pump flow.
    • The inlet hose must be a reinforced type; regular garden hose will collapse and lead to pump failure.
    • A foot valve with a strainer should be used to maintain prime.
    • All connections in the inlet hose must be sealed to prevent air leaks, which reduce pump performance.
    • An adapter for garden hose thread is included for both inlet and outlet connections.
  • Boosting Water Pressure:
    • Connect the inlet pipe or hose to the pump, and the other end to the water supply.
    • Connect the outlet pipe or hose to the pump.
    • Use only reinforced high-pressure hose or pipe for the outlet. Do not run the pump with the outlet pipe or nozzle closed, as this can cause the hose to burst.
  • Priming:
    • Before starting, remove the priming port on the pump and fill it with water. Reinstall the priming port.
    • For boosting water pressure, do not remove the priming port; turn on the water supply.
  • Operation:
    • Turn the pump switch to the "off" position before plugging it in.
    • Insert the power cord directly into a GFCI outlet.
    • Turn the pump switch to the "on" position.
    • If the pump does not pump water within 5 minutes, turn it off and refill with clean water. If repeated attempts fail, check that the vertical distance to the water level is not over 20 feet, the suction line is airtight, and all valves in the suction and discharge lines are open.
    • Never run the pump dry, as this will cause seal failure.

Maintenance Features

  • Ventilation: Maintain adequate ventilation for the pump motor.
  • Lubrication: The motor bearings are permanently lubricated at the factory and do not require additional lubrication.
  • Winter Draining: To protect against freezing temperatures, the system must be drained.
    • Disconnect suction and discharge lines from the pump.
    • Remove the plug from the lower front face of the pump.
    • Drain all piping below the frost line or store piping indoors.
    • Store the pump indoors.
  • Troubleshooting: A detailed troubleshooting chart is provided to address common issues such as the motor not running, motor running hot, pump running but not delivering water, and pump not delivering full capacity. This chart includes possible causes and corrective actions.
    • Capacitor Safety: A warning is given regarding hazardous capacitor voltage. To discharge the capacitor, short its terminals with an insulated screwdriver, ensuring to hold the handle of the screwdriver while making contact.
  • Warranty: The product comes with a one-year limited warranty from the date of purchase or two years from the date of manufacture, whichever occurs first. The warranty covers defects due to materials or workmanship. It does not cover failures due to improper installation, operation, maintenance, abuse, accident, negligence, use of inappropriate chemicals, normal maintenance services, or use for purposes other than its design. The manufacturer retains the sole right to repair or replace defective equipment. The warranty is valid in Canada and Mexico.

Replacement Parts

The only replacement part listed for Model HSPJ100 is the "Impeller, Diffuser, Nozzle Kit" with P/N 024609.

Star HSPJ100 Specifications

General IconGeneral
BrandStar
ModelHSPJ100
CategoryWater Pump
LanguageEnglish