110

 Diverts the ow of water past the water heater keeping water out of the
water heater.
Hot water bypass valve handle (B) should point away from water heater. (inline with the hot
water output).
Cold water bypass valve handle (A) should point away from the water heater. (inline with
the cold water supply)

The water heater switches are typically located on the monitor panel. Refer to the Monitor
Panel section for function details.

 Supplies fresh water to all xtures in the RV from a pressurized
water source attached to the fresh water connection inlet on the utility center panel.
1. The utility center tank ll / city water valve should be set to  position
(pointing down).
2. Water heater bypass valves should be set to the  position. Refer to appropri-
ate water heater bypass diagram for your model.
3. There are two valves at the water pump location. The water tank shuto valve (D)
should be in the OFF position (Fig 2). Siphon valve (E)) should be in the OFF posi-
tion (points away from clear hose). Fig 2 shows the siphon valve in the  position.
(Siphon valve is connected to the clear plastic hose).
4. The pump is not used with a pressurized water source so no water will be drawn from
the fresh water tank.
5. When the pressurized water source is turned on going to the utility center, water will
be distributed to all the xtures in the RV. 

 This setting will supply fresh water from the fresh water
tank to all xtures in the RV using the water pump.
1. The city water/tank ll valve is not used and
it can be left in  position when
the 12V water pump is being used to pull wa-
ter from the water tank.
2. Water tank shuto valve should be ON
(points in line with the water tank line). Si-
phon valve should be OFF (points away from
the clear hose). .
3. Water heater bypass should be set to the
 position.
4. When the water pump is turned ON, water
will be pulled out of the water tank and into the xtures. When a xture is opened, the
 Valve D is the fresh water tank shutoff valve. Valve E is the
siphon valve used for winterizing or sanitizing. Valves are located
near the water pump.

