SF-HC25C3 Height Controller
14
Modify multiple parameters to repeat 2, 3, 4, 5 steps and save them together.
When the input level setting error causes the failure to operate, press (GIVEN
VOLTAGE) button to add electricity to enter the parameter menu.
Declaration: parameter P00 can flashing status indicator light on/off on behalf of
the corresponding state of input signals, such as rose said the light tones to rise
on the input terminal block behind the signal is low (connected with 24G).
Enhanced parameter list
Above
LED
Below
LED
Set the
range
instruction
P00 0 0-4
0 do not save, 1 save, 2 restore user default, 3
restore factory default value, 4 save as user
default value
P01 2.0
0.1-9.9
Unit: V. Accuracy of arc pressure adjustment.
P02 5
1-10
The sensitivity coefficient, the greater the
coefficient, the higher the sensitivity.
P03 80
10-99 Manual (CNC) increase speed, 0 min, 99 Max.
P04 80
10-99 Manual (CNC) drop speed, 0 min, 99 Max.
P05 80
10-99
Automatic rising speed, 0 min, 99 Max.
P06 80
10-99
Automatic descent speed, 10 min, 99 Max.
P07 80
10-99
Location down speed, 10 min, 99 Max.
P08 80
10-99
Locate the uplift speed, 10 min, 99 Max.
P09 50
0-99
Unit: V (V), the arc feedback reference voltage
P10 0
0-9.9
Unit: second, double speed positioning speed
drop time.
P11 255
0-255
Unit: volt (V), arc voltage protection voltage.
P15 0
0-1
Motor forward and reverse switching.
P16 0
0-20
Braking force.
P17 10
0-10
Unit: seconds, impact time, 0 do not use this
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn