Partial pressure board uses four M3 screw to install, installation dimensions as
shown in figure 3-1-7. H is not less than 10MMabout installation requirements.
Figure 3-1-7
3.2 Electrical installation and connect
3.2.1 interface definition description
Table 3-2-1connect lifting mechanism
No. Character Illustration
Remark
MOT+ Output Lifting motor +
MOT- Output Lifting motor -
24V+ Output For 3 lines close to the switch
No use for others
Zero Input Initial location input - proximity switch
Limit+ Input Up limited location
Limit- Input Down limited location
COM Public port Positioning, the public port of the limit switch