EasyManua.ls Logo

State Water Heaters Utra-Force STC-077 - User Manual

State Water Heaters Utra-Force STC-077
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
THIS PRINTOUT IS FOR REFERENCE ONLY!
Do not use this printout for color match or critical dimensions.
PRINTOUT MADE AT 100% OF FINAL SIZE.
THIS FILE HAS NOT BEEN TRAPPED.
This file was created with Adobe Illustrator 8.0.1.
DO NOT try to open this
file with earlier versions.
Marketing Support Inc. assumes no responsibility for final print
quality and will not be held liable for errors or omissions due to
alterations made to this document by client,
film or print vendor.
MSI requires a Chromalin or color key type proof for
final approval.
If you have any questions about this file,
or require further assistance, contact MSI at 312-565-0044.
CMYK DIE
Job #: SWHM 104729
File Name: 104729_SrvcBk_UltraForc.ai
Size: 8.5
wide x 11 high
ProLeader: Nichole
Updates: jpc7.16.04tyr, NF 8.12.04
8 1/2
11
M O D E L S C O V E R E D
S U F 1 0 0 1 5 0 N E
S U F 1 0 0 1 9 9 N E
S U F 1 0 0 2 4 0 N E
The Experts Choice®
COMMERCIAL
The Experts Choice®
COMMERCIAL
The Expert’s Choic
COMMERCIAL
C o m m e rc ia l G a s W a te r H e a te rs
W ith 9 4 % Th erm a l E ffic ie n c y a n d
E le c tro n ic C o n tro l S yste m
P a rt N u m b e r S T C -0 7 7
$ 1 5 - P rin te d in th e U .S .A . - 0 9 0 4
S ta te W a te r H e a te rs
5 0 0 Lin dah l P ark w a y
A shlan d C ity
, T N 3 7 0 1 5
8 0 0 -3 6 5 -8 1 7 0
w w w .sta tew ate rh eaters.com
S E R V IC E H A N D B O O K
U ltra -F o rc e
A ls o in c lu d e s P a rts L is t
P rep ared b y th e S ta te W a te r H ea ters Train in g D e pa rtm en t.
Fo r ad ditio na l te ch n ica l info rm a tio n ca ll 8 0 0 -3 6 5 -0 5 77.
S ta te W a te r H e a te rs
5 0 0 Lin dah l P arkw ay
A sh la nd C ity, T N 3 7 0 1 5
8 0 0 -3 6 5 -8 1 7 0
w w w .sta tew ate rh ea te rs.co m
P rep ared b y th e S ta te W a ter H ea te rs Train in g D ep artm en t.
Fo r ad ditio na l te ch n ica l info rm a tio n ca ll 8 0 0 -3 6 5 -0 5 77.
© C o pyrig ht 2 0 0 4 S ta te In d u stries, In c.

Questions and Answers

  • M
    Matthew ClarkAug 18, 2025
    What to do if the low gas pressure switch does not show continuity in my State Water Heaters Utra-Force STC-077 Water Heater?
    • J
      Jason BatesAug 18, 2025
      If the low gas pressure switch on your State Water Heaters Water Heater doesn't show continuity, check for the minimum supply gas pressure of 5.0” W.C. for natural gas or 9.0” W.C. for LP gas. If the gas pressures are above these minimums, replace the switch.
  • M
    Mark CochranAug 20, 2025
    What to do if there is no continuity between terminals on pressure switches in my State Water Heaters Utra-Force STC-077?
    • B
      Brittney KaiserAug 21, 2025
      If continuity is not present between terminals on one or more pressure switches in your State Water Heaters Water Heater: * If the pressure recorded is within the value shown in the table for the switch contacts to remain closed, replace the pressure switch. * If the pressure recorded is not within the value shown in the table for the switch contacts to remain closed, check for and clear any restrictions in the vent and/or air intake piping and check for and restore minimum supply gas pressure.
  • M
    Michelle MarquezAug 23, 2025
    What to do if 24 VAC is not present between pin 1 on CN3 plug and ground in State Water Heaters Utra-Force STC-077 Water Heater?
    • D
      Debra GonzalesAug 23, 2025
      If 24 VAC is not present between pin 1 on the CN3 plug and ground on your State Water Heaters Water Heater, first ensure the water temperature in the tank is below 160° F. Then, press the Set/Reset button on the display panel. If the tank water temperature is below 160 and the previous steps were successful, replace the upper temperature/ECO probe.
  • A
    Ashley CollinsAug 26, 2025
    How to restore power to the control board on State Water Heaters Utra-Force STC-077 Water Heater?
    • M
      Madison GoodmanAug 26, 2025
      If 120 VAC is not present to the control board of your State Water Heaters Water Heater, check the On/Off switch and turn it on. If the switch is defective, replace it. Also, ensure that power is restored to the water heater.
  • T
    Tracy Turner DVMAug 28, 2025
    What to do if 120 VAC is not present to the ignitor from pin 1 and 2 on control board terminal CN5 on State Water Heaters Utra-Force STC-077?
    • H
      Heather KirkAug 28, 2025
      If 120 VAC is not present to the ignitor from pin 1 and 2 on control board terminal CN5 of your State Water Heaters Water Heater, replace the control board if previous steps have been performed and results were successful.
  • R
    Rebecca MathisAug 31, 2025
    What to do if 120 VAC is not present to the transformer from the control board in State Water Heaters Utra-Force STC-077 Water Heater?
    • S
      stephanie51Aug 31, 2025
      If 120 VAC is not present to the transformer from the control board of your State Water Heaters Water Heater, check the CN1 plug connection. If that doesn't solve the issue, replace the control board.
  • B
    Brenda MarquezSep 2, 2025
    What to do if 120 VAC is not present to blower from CN2 plug pin 1 and 2 in State Water Heaters Utra-Force STC-077?
    • M
      Michael MckenzieSep 2, 2025
      If 120 VAC is not present to the blower from CN2 plug pin 1 and 2 on your State Water Heaters Water Heater, replace the control board if the call for heat is active and previous steps have been performed successfully.
  • B
    bowmanmistySep 4, 2025
    What to do if 24 VAC is not present at transformer CN4 plug on control board in State Water Heaters Utra-Force STC-077?
    • T
      Timothy FernandezSep 5, 2025
      If 24 VAC is not present at the transformer CN4 plug on the control board of your State Water Heaters Water Heater, replace the transformer if previous steps were performed and successful.
  • A
    April WeissSep 7, 2025
    What to do if 24 VAC is not present between pin 4 on control board terminal CN3 and ground in State Water Heaters Utra-Force STC-077?
    • R
      Richard WongSep 7, 2025
      If 24 VAC is not present between pin 4 on the control board terminal CN3 and ground in your State Water Heaters Water Heater, replace the control board if previous steps have been performed and the results were successful.
  • D
    Dale LopezSep 9, 2025
    What to do if blocked inlet switch does not show continuity in State Water Heaters Water Heater?
    • J
      Jodi AlvarezSep 10, 2025
      If the blocked inlet switch on your State Water Heaters Water Heater does not show continuity, replace the switch.

Summary

INSTALLATION

OPERATION

SEQUENCE OF OPERATION

Describes the step-by-step heating cycle from call for heat to standby.

TROUBLESHOOTING

PRE-SERVICE TIPS

Essential checks and conditions to verify before starting troubleshooting.

120 VAC TO CONTROL

Tests for 120 VAC power supply at the control board's CN1 terminal.

TRANSFORMER

Checks for 120 VAC input and 24 VAC output from the transformer.

ECO CHECK

Verifies 24 VAC presence at the ECO probe and ensures proper function.

TEMPERATURE PROBE

Checks the resistance of the upper and lower temperature probes.

PRESSURE SWITCH CONTINUITY

Tests for continuity between pressure switch terminals.

BLOWER

Checks for 120 VAC power supply to the blower motor.

PRESSURE SWITCH PERFORMANCE

Measures air and gas pressures and checks switch continuity during operation.

120 VAC TO IGNITOR

Tests for 120 VAC power supply to the ignitor during warm-up.

IGNITOR RESISTANCE CHECK

Measures the resistance of the hot surface ignitor (HSI).

GAS VALVE TEST

Checks for 24 VAC supply to the gas valve during ignition trial.

COMPONENT INFORMATION

WIRING DIAGRAMS

ERROR CODES

SERVICE CHECKLIST

State Water Heaters Utra-Force STC-077 Specifications

General IconGeneral
BrandState Water Heaters
ModelUltra-Force STC-077
Tank Capacity77 gallons
Maximum Temperature180°F
Voltage480V
InsulationNon-CFC foam