14
close the water tank again when the appliance should be used
again, else the water tank should dry up completely.
Scale remains at the base, the transductor and the water tank
should be wiped away. It is essential, that the transductor is not
damaged. When there is excessive scale some scale remover
should be used or fill vinegar in the bassin. After some time, de-
pending on deposit, the scale dissolved. After this the base must
be cleaned completely with clean water. The filter should be put
into salty water (1 spoon salt per litre) for one day for recovery.
Then rinse the filter with clear water and shake it and then let it
dry.
Before the first use:
After a longer non use of the appliance the water filter should be placed for 20 min
in salty water. The bottom of the water tank and the water basin is with a nanosilver
structure and reduces the growth of bacteria. Positive ions make the water softer.
Important note - Filling in of water:
The tank cap with the water filter is opened by turning the tank cap counter-clockwi-
se (it is located under the water tank No. 9). Then you can fill in cold water in the filler
neck. Tightly close the tank cap with the water filter. Place the water tank correctly
on the support No. 15 so that it can properly work.
Start-up of the device:
Connect the plug with the mains socket. A beep sound is heard, and the display
shows the current room temperature and humidity, and standby is indicated in red
in the top left corner of the display. The water tank is lit by a blue LED. The standby
operation consumes 1 watt.
Press the Power button . The standby symbol disappears from the display, and
your air humidifier starts immediately. 1-6 bars are shown on the display, and water
vapour comes down from the water tank through the directed nozzles (No. 1) which
you may turn by 360 degrees.
When no or not enough water is left in the tank, just a red drip is flashing on the
display, and 3 beeps sounds can be heard from the device. Refill water as described
in (Filling in of water). The device re-starts immediately after the full water tank has
been placed in position again.